Set the FC or UTA/UTA2 configuration on node3
If node3 has onboard FC ports, onboard unified target adapter (UTA/UTA2) ports, or a UTA/UTA2 card, you must configure the settings before completing the rest of the procedure.
You might need to complete Configure FC ports on node3, or Check and configure UTA/UTA2 ports on node3, or both sections.
NetApp marketing materials might use the term "UTA2" to refer to CNA adapters and ports. However, the CLI uses the term "CNA". |
-
If node3 does not have onboard FC ports, onboard UTA/UTA2 ports, or a UTA/UTA2 card, and you are upgrading a system with storage disks, you can skip to the Map ports from node1 to node3.
-
However, if you have a V-Series system or a system with FlexArray Virtualization software with storage arrays, and node3 does not have onboard FC ports, onboard UTA/UTA ports, or a UTA/UTA2 card, return to Install and boot node3 and resume at Step 22.
Configure FC ports on node3
If node3 has FC ports, either onboard or on an FC adapter, you must set port configurations on the node before you bring it into service because the ports are not preconfigured. If the ports are not configured, you might experience a disruption in service.
You must have the values of the FC port settings from node1 that you saved in Prepare the nodes for upgrade.
You can skip this section if your system does not have FC configurations. If your system has onboard UTA/UTA2 ports or a UTA/UTA2 card, you configure them in Check and configure UTA/UTA2 ports on node3.
If your system has storage disks, enter the commands in this section at the cluster prompt. If you have a V-Series system or have FlexArray Virtualization Software and are connected to storage arrays, enter commands in this section in maintenance mode. |
-
Take one of the following actions:
If the system that you are upgrading… Then… Has storage disks
Go to Step 5
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
Go to Step 2
-
Boot node3 and access maintenance mode:
boot_ontap maint
-
Take one of the following actions:
If the system that you are upgrading… Then… Has storage disks
Enter the following command:
system node hardware unified-connect show
Is a V-series system or has FlexArray Virtualization Software and is connected to storage arrays.
Enter the following command
ucadmin show
The system displays information about all FC and converged network adapters on the system.
-
Compare the FC settings of node3 with the settings that you captured earlier from node1.
-
Take one of the following actions:
If the default FC settings on the new nodes are… Then… The same as the ones you that captured on node1
Go to Step 11.
Different from the ones that you captured on node1
Go to Step 6.
-
Take one of the following actions:
If the system that you are upgrading… Then… Has storage disks
Modify the FC ports on node3 as needed by entering one of the following commands:
-
To program target ports:
system node hardware unified-connect modify -type | -t target -adapter port_name
-
To program initiator ports:
system node hardware unified-connect modify -type | -t initiator -adapter port_name
-t
is the FC4 type: target or initiator.Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
Modify the FC ports on node3 as needed by entering the following command:
ucadmin modify -m fc -t initiator -f adapter_port_name
-t
is the FC4 type, target or initiator.The FC ports must be programmed as initiators. -
-
Take one of the following actions:
If the system that you are upgrading… Then… Has storage disks
Verify the new settings by entering the following command and examining the output:
system node hardware unified-connect show
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
Verify the new settings by entering the following command and examining the output:
ucadmin show
-
Exit maintenance mode by entering the following command:
halt
-
After you enter the command, wait until the system stops at the boot environment prompt.
-
Take one of the following actions:
If the system you are upgrading… Then… Is a V-Series system or has FlexArray Virtualization software running clustered Data ONTAP 8.3
Boot node3 and access maintenance at the boot environment prompt:
boot_ontap maint
Is not a V-Series system or does not have FlexArray Virtualization software
Boot node3 at the boot environment prompt:
boot_ontap
-
Take one of the following actions:
If the system that you are upgrading… Then… Has storage disks
-
If node3 has a UTA/UTA2 card or UTA/UTA2 onboard ports, go to Check and configure UTA/UTA2 ports on node3.
-
If node3 does not have a UTA/UTA2 card or UTA/UTA2 onboard ports, skip Check and configure UTA/UTA2 ports on node3 and go to Map ports from node1 to node3.
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
-
If node3 has a card or onboard ports, go to Check and configure UTA/UTA2 ports on node3.
-
If node3 does not have a card or onboard ports, skip Check and configure UTA/UTA2 ports on node3, and return to Install and boot node3 and resume at Step 7.
-
Check and configure UTA/UTA2 ports on node3
If node3 has onboard UTA/UTA2 ports or a UTA/UTA2 card, you must check the configuration of the ports and possibly reconfigure them, depending on how you want to use the upgraded system.
You must have the correct SFP+ modules for the UTA/UTA2 ports.
If you want to use a Unified Target Adapter (UTA/UTA2) port for FC, you must first verify how the port is configured.
NetApp marketing materials might use the term UTA2 to refer to CNA adapters and ports. However, the CLI uses the term CNA. |
You can use the ucadmin show
command to verify the current port configuration:
*> ucadmin show Current Current Pending Pending Admin Adapter Mode Type Mode Type Status ------- ------- --------- ------- --------- ----------- 0e fc target - initiator offline 0f fc target - initiator offline 0g fc target - initiator offline 0h fc target - initiator offline 1a fc target - - online 1b fc target - - online 6 entries were displayed.
UTA/UTA2 ports can be configured into native FC mode or UTA/UTA2 mode. FC mode supports FC initiator and FC target; UTA/UTA2 mode enables concurrent NIC and FCoE traffic sharing the same 10GbE SFP+ interface and supports FC targets.
UTA/UTA2 ports might be found on an adapter or on the controller, and have the following configurations, but you should check the configuration of the UTA/UTA2 ports on the node3 and change it, if necessary:
-
UTA/UTA2 cards ordered when the controller is ordered are configured before shipment to have the personality you request.
-
UTA/UTA2 cards ordered separately from the controller are shipped with the default FC target personality.
-
Onboard UTA/UTA2 ports on new controllers are configured before shipment to have the personality you request.
Attention: If your system has storage disks, you must enter the commands in this section at the cluster prompt unless directed to enter maintenance mode. If you have a VSeries system or have FlexArray Virtualization Software and are connected to storage arrays, you must enter commands in this section at the maintenance mode prompt. You must be in maintenance mode to configure UTA/UTA2 ports.
-
Check how the ports are currently configured entering on of the following commands on node3:
If the system… Then… Has storage disks
system node hardware unified-connect show
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
ucadmin show
The system displays output similar to the following examples:
cluster1::> system node hardware unified-connect show Current Current Pending Pending Admin Node Adapter Mode Type Mode Type Status ---- ------- ------- --------- ------- ------- ------ f-a 0e fc initiator - - online f-a 0f fc initiator - - online f-a 0g cna target - - online f-a 0h cna target - - online f-b 0e fc initiator - - online f-b 0f fc initiator - - online f-b 0g cna target - - online f-b 0h cna target - - online 12 entries were displayed.
*> ucadmin show Current Current Pending Pending Admin Adapter Mode Type Mode Type Status ------- ------- --------- ------- ------- ------ 0e fc initiator - - online 0f fc initiator - - online 0g cna target - - online 0h cna target - - online 0e fc initiator - - online 0f fc initiator - - online 0g cna target - - online 0h cna target - - online *>
-
If the current SFP+ module does not match the desired use, replace it with the correct SFP+ module.
Contact your NetApp representative to obtain the correct SFP+ module.
-
Examine the output of the
system node hardware unified-connect show
orucadmin show
command to determine whether the UTA/UTA2 ports have the personality you want. -
Take one of the following actions:
If the UTA/UTA2 ports… Then… Do not have the personality that you want
Go to Step 5.
Have the personality that you want
Skip Step 5 through Step 12 and go to Step 13.
-
Take one of the following actions:
If the system… Then… Has storage disks and is running clustered Data ONTAP 8.3
Boot node3 and enter maintenance mode:
boot_ontap maint
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
Go to Step 6.
You should already be in maintenance mode. -
Take one of the following actions:
If you are configuring… Then… Ports on a UTA/UTA2 card
Go to Step 7.
Onboard UTA/UTA2 ports
Skip Step 7 and go to Step 8.
-
If the adapter is in initiator mode, and if the UTA/UTA2 port is online, take the UTA/UTA2 port offline:
storage disable adapter adapter_name
Adapters in target mode are automatically offline in maintenance mode.
-
If the current configuration does not match the desired use, change the configuration as needed:
ucadmin modify -m fc|cna -t initiator|target adapter_name
-
-m
is the personality mode,fc
orcna
. -
-t
is the FC4 type,target
orinitiator
.You need to use the FC initiator for tape drives, FlexArray Virtualization systems, and MetroCluster configurations. You need to use the FC target for SAN clients.
-
-
Verify the settings:
ucadmin show
-
Verify the settings:
If the system… Then… Has storage disks
-
Stop the system:
halt
The system stops at the boot environment prompt.
-
Enter the following command:
boot_ontap
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
Reboot to maintenance mode:
boot_netapp maint
-
-
If the system… Then… Has storage disks
system node hardware unified-connect show
Is a V-Series or has FlexArray Virtualization Software and is connected to storage arrays
ucadmin show
The output in the following examples show that the FC4 type of adapter "1b" is changing to
initiator
and that the mode of adapters "2a" and "2b" is changing tocna
:cluster1::> system node hardware unified-connect show Current Current Pending Pending Admin Node Adapter Mode Type Mode Type Status ---- ------- ------- --------- ------- ----------- ------ f-a 1a fc initiator - - online f-a 1b fc target - initiator online f-a 2a fc target cna - online f-a 2b fc target cna - online 4 entries were displayed.
*> ucadmin show Current Current Pending Pending Admin Adapter Mode Type Mode Type Status ------- ------- --------- ------- --------- ------ 1a fc initiator - - online 1b fc target - initiator online 2a fc target cna - online 2b fc target cna - online *>
-
Place any target ports online by entering one of the following commands, once for each port:
If the system… Then… Has storage disks
network fcp adapter modify -node node_name -adapter adapter_name -state up
Is a V-Series system or has FlexArray Virtualization Software and is connected to storage arrays
fcp config adapter_name up
-
Take one of the following actions:
If the system… Then… Has storage disks
Is a V-series system or has FlexArray Virtualization Software and is connected to storage arrays
Return to Install and boot node3 and resume at Step 7.