Skip to main content

Upgrading SANtricity OS on the storage controllers using maintenance mode

Contributors netapp-lhalbert

For storage controllers currently using SANtricity OS older than 08.42.20.00 (11.42), you must use the maintenance mode procedure to apply an upgrade.

What you'll need
  • You have consulted the NetApp Interoperability Matrix Tool (IMT) to confirm that the SANtricity OS version you are using for the upgrade is compatible with your appliance.

  • If the StorageGRID appliance is running in a StorageGRID system, the SG6000-CN controller has been placed in maintenance mode.

    Note Maintenance mode interrupts the connection to the storage controller.
About this task

Do not upgrade the SANtricity OS or NVSRAM in the E-Series controller on more than one StorageGRID appliance at a time.

Important Upgrading more than one StorageGRID appliance at a time might cause data unavailability, depending on your deployment model and ILM policies.
Steps
  1. From a service laptop, access SANtricity System Manager and sign in.

  2. Download the new SANtricity OS Software file and NVSRAM file to the management client.

    Important The NVSRAM is specific to the StorageGRID appliance. Do not use the standard NVSRAM download.
  3. Follow the instructions in the Upgrading SANtricity OS guide or the SANtricity System Manager online help to upgrade the firmware and NVSRAM.

    Note Activate the upgrade files immediately. Do not defer activation.
  4. Once the upgrade operation has completed, reboot the node. From the StorageGRID Appliance Installer, select Advanced > Reboot Controller, and then select one of these options:

    • Select Reboot into StorageGRID to reboot the controller with the node rejoining the grid. Select this option if you are done working in maintenance mode and are ready to return the node to normal operation.

    • Select Reboot into Maintenance Mode to reboot the controller with the node remaining in maintenance mode. Select this option if there are additional maintenance operations you need to perform on the node before rejoining the grid. Reboot controller in maintenance mode

      It can take up to 20 minutes for the appliance to reboot and rejoin the grid. To confirm that the reboot is complete and that the node has rejoined the grid, go back to the Grid Manager. The Nodes tab should display a normal status icon alert green checkmark for the appliance node, indicating that no alerts are active and the node is connected to the grid.

      Appliance node rejoined grid