Skip to main content
A newer release of this product is available.

Send E-Series AutoSupport packages through StorageGRID

Contributors netapp-lhalbert netapp-madkat netapp-pcarriga netapp-perveilerk

You can send E-Series SANtricity System Manager AutoSupport packages to technical support through a StorageGRID Admin Node rather than the storage appliance management port.

See E-Series hardware AutoSupport for more information about using AutoSupport with E-Series appliances.

Before you begin
Note You must have SANtricity firmware 8.70 or higher to access SANtricity System Manager using the Grid Manager.
About this task

E-Series AutoSupport packages contain details of the storage hardware and are more specific than other AutoSupport packages sent by the StorageGRID system.

You can configure a special proxy server address in SANtricity System Manager to transmit AutoSupport packages through a StorageGRID Admin Node without the use of the appliance's management port. AutoSupport packages transmitted in this way are sent by the preferred sender Admin Node, and they use any admin proxy settings that have been configured in the Grid Manager.

Note This procedure is only for configuring a StorageGRID proxy server for E-Series AutoSupport packages. For additional details on E-Series AutoSupport configuration, see the NetApp E-Series and SANtricity Documentation.
Steps
  1. In the Grid Manager, select NODES.

  2. From the list of nodes on the left, select the storage appliance node you want to configure.

  3. Select SANtricity System Manager.

    The SANtricity System Manager home page appears.

    AutoSupport SANtricity home page
  4. Select SUPPORT > Support center > AutoSupport.

    The AutoSupport operations page appears.

    AutoSupport SANtricity AutoSupport operations
  5. Select Configure AutoSupport Delivery Method.

    The Configure AutoSupport Delivery Method page appears.

    AutoSupport configure AutoSupport delivery method SANtricity
  6. Select HTTPS for the delivery method.

    Note The certificate that enables HTTPS is pre-installed.
  7. Select via Proxy server.

  8. Enter tunnel-host for the Host address.

    tunnel-host is the special address to use an Admin Node to send E-Series AutoSupport packages.

  9. Enter 10225 for the Port number.

    10225 is the port number on the StorageGRID proxy server that receives AutoSupport packages from the E-Series controller in the appliance.

  10. Select Test Configuration to test the routing and configuration of your AutoSupport proxy server.

    If correct, a message in a green banner appears: "Your AutoSupport configuration has been verified."

    If the test fails, an error message appears in a red banner. Check your StorageGRID DNS settings and networking, ensure the preferred sender Admin Node can connect to the NetApp Support Site, and try the test again.

  11. Select Save.

    The configuration is saved, and a confirmation message appears: "AutoSupport delivery method has been configured."