步骤
  1. 在加载程序提示符处、将node3启动至维护模式:

    boot_ontap maint

  2. 显示100GbE接口的状态:

    storage port show

  3. 将100GbE接口设置为存储端口:

    storage port modify -p e0c -m storage

    storage port modify -p e0d -m storage

  4. 验证100GbE接口的模式更改:

    storage port show

    应显示如下示例所示的输出:

    *> storage port modify -p e0c -m storage
    Nov 10 16:27:23 [localhost:nvmeof.port.modify:notice]: Changing NVMe-oF port e0c to storage mode.
    
    Nov 10 16:27:29 [localhost:nvmeof.subsystem.add:notice]: NVMe-oF subsystem added at address fe80::2a0:98ff:fefa:8885.
    
    *> storage port modify -p e0d -m storage
    Nov 10 16:27:34 [localhost:nvmeof.port.modify:notice]: Changing NVMe-oF port e0d to storage mode.
    
    Nov 10 16:27:38 [localhost:nvmeof.subsystem.add:notice]: NVMe-oF subsystem added at address fe80::2a0:98ff:fefa:8886.
    
    *> storage port show
    Port Type Mode    Speed(Gb/s) State    Status  VLAN ID
    ---- ---- ------- ----------- -------- ------- -------
    e0c  ENET storage 100 Gb/s    enabled  online  30
    e0d  ENET storage 100 Gb/s    enabled  offline 30
  5. 显示所有连接的驱动器:

    disk show -v

  6. 记录本地系统ID值;这是node3的系统ID。另外、请记录"owner"列中node1和node2的系统ID。

  7. 将所有驱动器从node1重新分配到node3:

    disk reassign -s node1_system_ID -d node3_system_ID -p node4_system_ID

  8. 验证所有重新分配的驱动器是否可供新系统ID查看:

    disk show -s node3_system_ID

    备注 如果无法查看驱动器、请执行*停止*并联系技术支持以获得帮助。
  9. 退出维护模式:

    halt