A newer release of this product is available.
        
        
      storage failover hwassist test
Test the hwassist functionality
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The ` storage failover hwassist test` command tests the Hardware Assist h/w connectivity between the two nodes in a HA pair. The test result can be one of the following.
- 
Hardware Assist is not initialized. 
- 
HW assist is not supported. 
- 
Partner is throttling alerts. 
- 
Resource is busy. 
- 
Hardware Assist h/w returned an error. 
- 
No response from partner.Timed out. 
- 
Unexpected abort. 
- 
Partner has taken over. 
- 
Interconnect is down between nodes. 
- 
Partner is not booted up yet. 
Parameters
- -node {<nodename>|local}- Node
- 
This specifies the node from which a test alert is initiated. 
Examples
The following command issues a test alert from the node cluster1-01:
cluster1::> storage failover hwassist test -node cluster1-01 Info: Operation successful.