storage tape show-errors
Display tape drive errors
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage tape show-errors command displays error information about tape drives attached to the cluster. By default, this command displays the following information about all tape drives:
-
Node to which the tape drive is attached
-
Device ID of the tape drive
-
Type of device(tape drive)
-
Description of the tape drive
-
Alias name of the tape drive
-
Tape drive errors
Parameters
- {
[-fields <fieldname>,…] -
If you specify the
-fields <fieldname>, …parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]} -
If you specify the
-instanceparameter, the command displays detailed information about all fields. [-node {<nodename>|local}]- Node-
Displays detailed information about tape drives on the specified node.
[-device-id <text>]- Device ID-
Selects the tape drive with the specified device ID.
[-device-type <text>]- Device Type-
Selects the devices with the specified type of tape drive.
[-description <text>]- Description-
Selects the tape drives with the specified description.
[-alias-name <text>]- Alias Name-
Selects the tape drive with the specified alias name.
[-wwnn <text>]- World Wide Node Name-
Selects the tape drives with the specified World Wide Node Name.
[-wwpn <text>]- World Wide Port Name-
Selects the tape drive with the specified World Wide Port Name.
[-serial-number <text>]- Serial Number-
Selects the tape drive with the specified serial number.
[-error <text>]- Tape Drive Error Description-
Selects the tape drives with the specified error string.
[-initiator <text>]- Initiator Port-
Selects the tape drives with the specified initiator port.
Examples
The following example shows error information for all tape drives attached to cluster1.
cluster1::> storage tape show-errors
Node: node1
Device ID: 0d.125
Device Type: tape drive
Description: Hewlett-Packard LTO-5
Alias: st0
Errors: hardware error; repair or replace tape drive
Node: node1
Device ID: 2d.0
Device Type: tape drive
Description: IBM LTO-6 ULT3580
Alias: st2
Errors: -
The following example shows error information for tape drive sw4:2.126L1 attached to the node, node1.
cluster1::> storage tape show-errors -device-id sw4:2.126L1 -node node1
Node: node1
Device ID: sw4:2.126L1
Device Type: tape drive
Description: Hewlett-Packard LTO-3
Alias: st3
Errors: -