storage tape show-errors
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Display tape drive errors
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage tape show-errors
command displays error information about tape drives attached to the cluster. By default, this command displays the following information about all tape drives:
-
Node to which the tape drive is attached
-
Device ID of the tape drive
-
Type of device(tape drive)
-
Description of the tape drive
-
Alias name of the tape drive
-
Tape drive errors
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
Displays detailed information about tape drives on the specified node.
[-device-id <text>]
- Device ID-
Selects the tape drive with the specified device ID.
[-device-type <text>]
- Device Type-
Selects the devices with the specified type of tape drive.
[-description <text>]
- Description-
Selects the tape drives with the specified description.
[-alias-name <text>]
- Alias Name-
Selects the tape drive with the specified alias name.
[-wwnn <text>]
- World Wide Node Name-
Selects the tape drives with the specified World Wide Node Name.
[-wwpn <text>]
- World Wide Port Name-
Selects the tape drive with the specified World Wide Port Name.
[-serial-number <text>]
- Serial Number-
Selects the tape drive with the specified serial number.
[-error <text>]
- Tape Drive Error Description-
Selects the tape drives with the specified error string.
[-initiator <text>]
- Initiator Port-
Selects the tape drives with the specified initiator port.
Examples
The following example shows error information for all tape drives attached to cluster1.
cluster1::> storage tape show-errors Node: node1 Device ID: 0d.125 Device Type: tape drive Description: Hewlett-Packard LTO-5 Alias: st0 Errors: hardware error; repair or replace tape drive Node: node1 Device ID: 2d.0 Device Type: tape drive Description: IBM LTO-6 ULT3580 Alias: st2 Errors: -
The following example shows error information for tape drive sw4:2.126L1 attached to the node, node1.
cluster1::> storage tape show-errors -device-id sw4:2.126L1 -node node1 Node: node1 Device ID: sw4:2.126L1 Device Type: tape drive Description: Hewlett-Packard LTO-3 Alias: st3 Errors: -