system ha interconnect status show
Display the high-availability interconnect connection status
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The system ha interconnect status show
command displays the high-availability interconnect connection status. Connection status information displayed by this command varies by controller model. For nodes with two HA interconnect links over the backplane or connected externally, this command displays the following information:
-
Node
-
Link status on the first port
-
Link status on the second port
-
Is the link on first port active?
-
Is the link on second port active?
-
Interconnect RDMA status
For nodes with a single HA interconnect link, this command displays following the information:
-
Node
-
Link status
-
Interconnect RDMA status
Running the command with the -instance
or -node
parameter displays detailed information about the interconnect device and its ports.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>,…
parameter, the command displays only the fields that you specify. - |
[-instance ]
} -
Use this parameter to display all the fields for the specified node or all the nodes.
[-node {<nodename>|local}]
- Node (privilege: advanced)-
Use this parameter to display all the fields for the specified node.
[-link-status {up|down}]
- Link Status (privilege: advanced)-
Selects the nodes that match this parameter value. The value
up
means link is online. [-link0-status {up|down}]
- Link 0 Status (privilege: advanced)-
Selects the nodes that match this parameter value. The value
up
means link is online. [-link1-status {up|down}]
- Link 1 Status (privilege: advanced)-
Selects the nodes that match this parameter value. The value
up
means link is online. [-ic-rdma {up|down}]
- IC RDMA Connection (privilege: advanced)-
Selects the nodes that match this parameter value. The value
up
means active interconnect connection with its partner. [-is-link0-active {true|false}]
- Is Link 0 Active (privilege: advanced)-
Selects the nodes that match this parameter value. The value
true
means the interconnect data channels are established on this link. [-is-link1-active {true|false}]
- Is Link 1 Active (privilege: advanced)-
Selects the nodes that match this parameter value. The value
true
means the interconnect data channels are established on this link. [-slot <integer>]
- Slot Number (privilege: advanced)-
Selects the nodes that match this PCI slot number.
[-driver-name <text>]
- Driver Name (privilege: advanced)-
Selects the nodes that match this interconnect device driver name.
[-firmware <text>]
- Firmware Revision (privilege: advanced)-
Selects the nodes that match this firmware version.
[-version <text>]
- Version Number (privilege: advanced)-
Selects the nodes that match this parameter value.
[-device-type <text>]
- Device Type (privilege: advanced)-
Selects the nodes that match this interconnect device type.
[-serial-number <text>]
- Serial Number (privilege: advanced)-
Selects the nodes that match this interconnect device serial number.
[-debug-firmware {yes|no}]
- Debug Firmware (privilege: advanced)-
Selects the nodes that match this parameter value.
[-command-revision <integer>]
- Command Revision (privilege: advanced)-
Selects the nodes that match this interconnect device command revision.
[-hardware-revision <integer>]
- Hardware Revision (privilege: advanced)-
Selects the nodes that match this interconnect device hardware revision.
[-port1 <integer>]
- Port Number 1 (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port1-port-name <text>]
- Port Name (privilege: advanced)-
Selects the nodes that match this port name.
[-port1-gid <text>]
- Global Identifier (privilege: advanced)-
Selects the nodes that match this global identifier value.
[-port1-base-lid <text>]
- Base Local Identifier (privilege: advanced)-
Selects the nodes that match this base local identifier value.
[-port1-rm-lid <text>]
- Remote Local Identifier (privilege: advanced)-
Selects the nodes that match this remote local identifier value.
[-port1-mtu <integer>]
- Maximum Transmission Unit (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port1-data-rate <text>]
- Data Rate (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port1-link-info <text>]
- Link Information (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port1-qsfp-vendor <text>]
- QSFP Vendor (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) vendor name.
[-port1-qsfp-part-number <text>]
- QSFP Part Number (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) part-number.
[-port1-qsfp-type <text>]
- QSFP Type (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) type.
[-port1-qsfp-serial-number <text>]
- QSFP Serial Number (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) serial number.
[-port2 <integer>]
- Port Number 2 (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port2-port-name <text>]
- Port Name (privilege: advanced)-
Selects the nodes that match this port name.
[-port2-gid <text>]
- Global Identifier (privilege: advanced)-
Selects the nodes that match this global identifier value.
[-port2-base-lid <text>]
- Base Local Identifier (privilege: advanced)-
Selects the nodes that match this base local identifier value.
[-port2-rm-lid <text>]
- Remote Local Identifier (privilege: advanced)-
Selects the nodes that match this remote local identifier value.
[-port2-mtu <integer>]
- Maximum Transmission Unit (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port2-data-rate <text>]
- Data Rate (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port2-link-info <text>]
- Link Information (privilege: advanced)-
Selects the nodes that match this parameter value.
[-port2-qsfp-vendor <text>]
- QSFP Vendor (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) vendor name.
[-port2-qsfp-part-number <text>]
- QSFP Part Number (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) part number.
[-port2-qsfp-type <text>]
- QSFP Type (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) type.
[-port2-qsfp-serial-number <text>]
- QSFP Serial Number (privilege: advanced)-
Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) serial number.
Examples
The following example displays status information about the HA interconnect connection on FAS8000 series nodes with two HA interconnect links in the cluster:
cluster1::*> system ha interconnect status show Node: ic-f8040-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: false IC RDMA Connection: up Node: ic-f8040-02 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: false IC RDMA Connection: up 2 entries were displayed.
The following example displays status information about the HA interconnect connection on FAS2500 series nodes with a single HA interconnect link in the cluster:
cluster1::*> system ha interconnect status show Node: ic-f2554-01 Link Status: up IC RDMA Connection: up Node: ic-f2554-02 Link Status: up IC RDMA Connection: up 2 entries were displayed.
The following example displays detailed information about the HA interconnect link when parameters like -instance
, -node
are used with the `system ha interconnect status show ` command
cluster1::*> system ha interconnect status show -instance -node ic-f8040-01 Node: ic-f8040-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: false IC RDMA Connection: up Slot: 0 Driver Name: IB Host Adapter i0 (Mellanox ConnectX MT27518 rev. 0) Firmware: 2.11.534 Debug Firmware: no Interconnect Port 0 : Port Name: ib0a GID: fe80:0000:0000:0000:00a0:9800:0030:33ec Base LID: 0x3ec MTU: 4096 Data Rate: 40 Gb/s (4X) QDR Link Information: ACTIVE Interconnect Port 1 : Port Name: ib0b GID: fe80:0000:0000:0000:00a0:9800:0030:33ed Base LID: 0x3ed MTU: 4096 Data Rate: 40 Gb/s (4X) QDR Link Information: ACTIVE