Display the Boot Media Device Health Status
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system controller bootmedia show
command displays details of the bootmedia devices present in all the nodes in a cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about the bootmedia:
-
Node name
-
Display name
-
Vendor ID
-
Device ID
-
Memory size
-
Bootmedia state
-
Health monitor status
To display more details, use the -instance parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Selects the fields that you specify.
- |
[-instance ]
} -
Displays detailed information for all the bootmedia devices.
[-node {<nodename>|local}]
- Node-
Selects the bootmedia device that is present on the specified node.
[-serial-num <text>]
- Serial Number-
Selects the bootmedia devices with the specified serial number.
[-vendor-id <Hex Integer>]
- Vendor ID-
Selects the bootmedia devices with the specified vendor ID.
[-device-id <Hex Integer>]
- Device ID-
Selects the bootmedia devices with the specified device ID.
[-display-name <text>]
- Display Name-
Selects the bootmedia devices with the specified display name.
[-unique-name <text>]
- Unique Name-
Selects the bootmedia device with the specified unique name.
[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example|ethernet-switch}]
- Health Monitor Name-
Selects the bootmedia devices with the specified health monitor.
[-usbmon-status {present|not-present}]
- Bootmedia Health Monitor-
Selects the bootmedia devices with the specified USBMON status.
[-device-state {good|warn|bad}]
- Bootmedia State-
Selects the bootmedia devices with the specified device state.
[-size <integer>]
- Max Memory Size (MB)-
Selects the bootmedia devices with the specified memory size.
[-health {ok|ok-with-suppressed|degraded|unreachable|unknown}]
- Status-
Selects the bootmedia devices with the specified health monitor status.
[-is-nvme {true|false}]
- Is NVMe Boot Media-
Selects the boot media technology. If the value is "true", the boot media uses NVMe technology.
[-nvme-percent-used <integer>]
- NVMe Percentage Used-
Selects the NVMe boot media with the specified percentage of rated life used by the solid-state device (SSD). When an SSD reaches 100% of rated life, it might not be able to retain data while powered off for long periods of time.
[-nvme-available-spare <integer>]
- NVMe Available Spare-
Selects the NVMe boot media with the specified percentage of available spare blocks. When all spare blocks are consumed on the SSD, i.e. when this parameter reaches 0%, the system can no longer write data to the solid-state device (SSD).
[-nvme-spare-threshold <integer>]
- NVMe Spare Threshold-
Selects the NVMe boot media with the specified "low spare blocks" threshold percentage. System health monitor alerts are generated when the available spare blocks on the SSD cross below this threshold.
Examples
The following example displays the information of the boot media present in all the nodes in a cluster:
cluster1::> system controller bootmedia show Size Bootmedia Node Display Name Vendor ID Device ID (MB) State Status ------------- -------------------- --------- --------- ------- --------- ------ node1 Micron Technology 634 655 1929 good ok 0x655 node2 Micron Technology 634 655 1929 good ok 0x655
The example below displays the detailed information about the bootmedia present in a node.
cluster1::> system controller bootmedia show -instance -node node1 Node: node1 Vendor ID: 634 Device ID: 655 Display Name: Micron Technology 0x655 Unique Name: Micron Technology 0x655 (ad.0) Health Monitor Name: controller USBMON Health Monitor: present Bootmedia State: good Max memory size(in MB): 1929 Status: ok Is NVMe: true NVMe Percentage Used: 0 NVMe Available Spare: 100 NVMe Spare Threshold: 10