network port vlan show
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Display virtual LANs (VLANs)
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The network port vlan show
command displays information about network ports that are attached to VLANs. The command output indicates any inactive links and lists the reason for the inactive status.
If the operational duplex mode and speed cannot be determined (for instance, if the link is down), they are listed as undef
, meaning undefined.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
Selects the VLAN network ports that match this parameter value.
- {
[-vlan-name {<netport>|<ifgrp>}]
- VLAN Name -
Selects the VLAN network ports that match this parameter value.
- |
[-port {<netport>|<ifgrp>}]
- Associated Network Port -
Selects the VLAN network ports that match this parameter value. If neither this parameter nor
-name
are used, the command displays information about all network ports. [-vlan-id <integer>]
- Network Switch VLAN Identifier }-
Selects the VLAN network ports that match this parameter value.
[-mac <MAC Address>]
- MAC address-
Selects the VLAN network ports that match this parameter value.
Examples
The example below shows VLAN e1b-70 attached to port e1b on node1.
cluster1::> network port vlan show Network Network Node VLAN Name Port VLAN ID MAC Address ------ --------- ------- ------- ------------------ node1 e1b-70 e1b 70 00:15:17:76:7b:69