network fcp adapter show
Display FCP adapters
Availability: This command is available to cluster administrators at the admin privilege level.
Description
Displays FCP target adapter information. You can also use this information to determine if adapters are active and online.
The adapter argument is in the form Xy or Xy_z where X and z are integers and y is a letter. An example is 4a or 4a_1.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
If this parameter is specified, the command displays information only about the FCP target adapters that are present on the specified node.
[-adapter <text>]
- Adapter-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified name.
[-description <text>]
- Description-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified description.
[-physical-protocol {fibre-channel|ethernet}]
- Physical Protocol-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified physical protocol. Possible values are
fibre-channel
andethernet
. [-max-speed {1|2|4|8|10|16|32|64|auto}]
- Maximum Speed-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified maxium speed.
[-status-admin {down|up}]
- Administrative Status-
If this parameter is specified, the command displays information only about the FCP target adapters that match the administrative state. Possible values are
up
anddown
. [-status-oper <text>]
- Operational Status-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified operational status.
[-status-extended <text>]
- Extended Status-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified extended status.
[-portaddr <Hex Integer>]
- Host Port Address-
If this parameter is specified, the command displays information only about the FCP target adapters connected with the specified fabric port address.
[-firmware-rev <text>]
- Firmware Revision-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified firmware revision.
[-data-link-rate <integer>]
- Data Link Rate (Gbit)-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified data link rate.
[-fabric-established {true|false}]
- Fabric Established-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified fabric login establishment state.
[-fabric-name <text>]
- Fabric Name-
If this parameter is specified, the command displays information only about the FCP target adapters that are logged in to the fabric with the specified WWN.
[-conn-established {loop|ptp}]
- Connection Established-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified connection type. Possible values are
loop
andptp
. [-is-conn-established {true|false}]
- Is Connection Established-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified connection established state.
[-media-type {loop|ptp|auto}]
- Mediatype-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified configured media type. Possible values are
loop
,ptp
, andauto
. [-speed {1|2|4|8|10|16|32|64|auto}]
- Configured Speed-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified configured speed. If the adapter is set to auto-negotiate, then the value will be
auto
. [-data-protocols-supported {fcp|fc-nvme}]
- Data Protocols Supported-
If this parameter is specified, the command displays information only about the FCP target adapters that may host LIFs with the specified data protocol. Possible values are
fcp
andfc-nvme
. [-domain-id <integer>]
- Domain ID-
If this parameter is specified, the command displays information only about the FCP target adapters with a domain identifier that matches the specified domain identifier.
[-fc-wwnn <text>]
- Adapter WWNN-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified world wide node name.
[-fc-wwpn <text>]
- Adapter WWPN-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified world wide port name.
[-switch-port <text>]
- Switch Port-
If this parameter is specified, the command displays information only about the FCP target adapters that are connected to the specified switch port.
[-sfp-formfactor <text>]
- Form Factor Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP form factor.
[-sfp-vendor-name <text>]
- Vendor Name Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP vendor name.
[-sfp-part-number <text>]
- Part Number Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP part number.
[-sfp-rev <text>]
- Revision Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP revision number.
[-sfp-serial-number <text>]
- Serial Number Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP serial number.
[-sfp-fc-speed-capabilities <text>]
- FC Capabilities Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP speed capabilities.
[-sfp-vendor-oui <text>]
- Vendor OUI Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP vendor OUI.
[-sfp-wavelength <integer>]
- Wavelength In Nanometers-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP wavelength.
[-sfp-date-code <text>]
- Date Code Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP date code.
[-is-sfp-optical-transceiver-valid {true|false}]
- Validity Of Transceiver-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the SFP is installed and valid.
[-sfp-connector <text>]
- Connector Used-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP connector type.
[-sfp-encoding <text>]
- Encoding Used-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP physical encoding.
[-is-sfp-diagnostics-internally-calibrated {true|false}]
- Is Internally Calibrated-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the SFP diagnostics are internally calibrated or not.
[-sfp-diagnostic-monitoring-type <Hex Integer>]
- Diagnostic Monitoring Type-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP diagnostic monitoring type.
[-sfp-ddm-capabilities <text>]
- Status Monitoring Available-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the specified SFP digital diagnostics monitoring are supported or not.
[-sfp-sff8472-compliance <Hex Integer>]
- SFF-8472 Compliance-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP SFF8472 compliance.
[-sfp-rx-power <text>]
- Received Optical Power-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified observed SFP receive power.
[-is-sfp-rx-power-in-range {true|false}]
- Is Received Power In Range-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the observed SFP receive power is within the valid range for the SFP.
[-sfp-tx-power <text>]
- SFP Transmitted Optical Power-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP transmit power.
[-is-sfp-tx-power-in-range {true|false}]
- Is Xmit Power In Range-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the observed SFP transmit power is within the valid range for the SFP.
[-sfp-ddm-status-control <Hex Integer>]
- DDM Status-
If this parameter is specified, the command displays information only about the FCP target adapters that match the specified SFP DDM status and control.
[-is-sfp-tx-in-disable {true|false}]
- Is Xmit Disabled-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the observed SFP transmitter is in disabled state.
[-is-sfp-tx-in-fault {true|false}]
- Is Xmit In Fault-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the observed SFP transmitter is in faulted state.
[-is-sfp-rx-in-los {true|false}]
- Is Receiver In LOS-
If this parameter is specified, the command displays information only about the FCP target adapters that match whether the observed SFP receiver is in loss of signal state.
Examples
cluster1::> fcp adapter show Connection Host Node Adapter Established Port Address ------------ ------- ----------- ------------ sti6280-021 0a ptp 30012c
The example above displays information regarding FCP adapters within cluster1.
cluster1::> fcp adapter show -instance -node sti6280-021 -adapter 0a Node: sti6280-021 Adapter: 0a Description: Fibre Channel Target Adapter 0a (QLogic 2532 (2562), rev. 2, 8G) Physical Protocol: fibre-channel Maximum Speed: 8 Administrative Status: up Operational Status: online Extended Status: ADAPTER UP Host Port Address: 30012c Firmware Revision: 5.8.0 Data Link Rate (Gbit): 4 Fabric Established: true Fabric Name: 20:14:54:7f:ee:54:b9:01 Connection Established: ptp Is Connection Established: true Mediatype: ptp Configured Speed: auto Adapter WWNN: 50:0a:09:80:8f:7f:8b:1c Adapter WWPN: 50:0a:09:81:8f:7f:8b:1c Switch Port: RTP-AG01-410B51:1/41 Form Factor Of Transceiver: SFP Vendor Name Of Transceiver: OPNEXT,INC Part Number Of Transceiver: TRS2000EN-SC01 Revision Of Transceiver: 0000 Serial Number Of Transceiver: T10H64793 FC Capabilities Of Transceiver: 10 (Gbit/sec) Vendor OUI Of Transceiver: 0:11:64 Wavelength In Nanometers: 850 Date Code Of Transceiver: 10:08:17 Validity Of Transceiver: true Connector Used: LC Encoding Used: 64B66B Is Internally Calibrated: true Diagnostic Monitoring Type: 68 Status Monitoring Available: fa {Rx_Loss_of_Sig, Tx_Fault, Tx_Disable} SFF-8472 Compliance: 5 Received Optical Power: 441.3 (uWatts) Is Received Power In Range: true SFP Transmitted Optical Power: 600.4 (uWatts) Is Xmit Power In Range: true DDM Status: 30 Is Xmit Disabled: false Is Xmit In Fault: false Is Receiver In LOS: false
The example above displays detailed information regarding FCP adapter 0a in sti6280-021 within cluster1.