vserver check lif-multitenancy show-results
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
(DEPRECATED)-Show the results of the latest multitenancy network run
Availability: This command is available to cluster and Vserver administrators at the admin privilege level.
Description
This command is deprecated and may be removed in a future release of Data ONTAP. |
You can view detailed information about the latest completed run, or the run for a Vserver.
-
Vserver - name of vserver run was for
-
Severity - severity of the message which is failure, warning, or info.
*
Failures are problems that need fixed. Warnings are potential
problems that may need to be fixed. Values are "failure", "warning" or "info". -
Service - name of service that is being checked for connectivity
-
Address - address of server configured for the above service that is being
*
checked for connectivity. -
LIF - the LIF a successful connectivity check to the above server was made from
-
Connected - true of there is connectivity, false if there is not
-
Status - additional information useful for resolving issues
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-vserver <vserver>]
- Vserver-
Selects the messages matching the specified Vserver
[-severity <text>]
- Severity-
Selects the messages matching the specified severity of failure, warning, and info.
[-service <text>]
- Service Name-
Selects the messages matching the specified service.
[-address <text>]
- Address of Server-
Selects the messages matching the specified address.
[-lif <lif-name>]
- Logical Interface-
Selects the messages matching the specified LIF.
[-connected {yes|no}]
- Vserver Connectivity-
Selects the messages matching the specified connectivity.
[-status <text>]
- Additional Information-
Selects the messages matching the specified search criteria.
Examples
Runs that are successful will not have any content.
cluster1::> vserver check lif-multitenancy show-results -vserver vs0 This table is currently empty.
Successful runs made with -verbose true will show the LIF used to Ping the nework address from.
cluster1::> vserver check lif-multitenancy show-results -vserver vs0 Network Logical Vserver Severity Service Address Interface Connected Status ---------- -------- ----------- ----------- --------- ---------- ------- vs0 info DNS 10.98.200.20 vs0_lif1 yes ping info NIS domain 10.98.13.53 vs0_lif1 yes ping 2 entries were displayed.
Runs that fail display each failure that needs to be fixed.
cluster1::> vserver check lif-multitenancy show-results -vserver vs0 Network Logical Vserver Severity Service Address Interface Connected Status ---------- -------- ----------- ----------- --------- ---------- ------- vs0 warning - - vs0_lif1 - operationally down warning - - vs0_lif2 - operationally down failure DNS 10.98.200.20 - no cache failure NIS domain 10.98.13.53 - no cache 4 entries were displayed.