Skip to main content

network interface failover-groups add-targets

Contributors
Suggest changes

Add failover targets to a failover group

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The network interface failover-groups add-targets command enables you to add a list of failover targets such as network ports, interface groups, or VLANs to an existing logical interface failover group.

Parameters

-vserver <vserver> - Vserver Name

Use this parameter to specify the name of the Vservers from which this failover group is accessible.

-failover-group <text> - Failover Group Name

Use this parameter to specify the failover group that you want to extend.

-targets [node>:<port],…​ - Failover Targets

Use this parameter to specify the failover targets such as network ports, interface groups, or VLANs you wish to add to the failover group.

Examples

This example shows the failover group "clyde" being extended to include additional failover targets.

cluster1::> network interface failover-group add-targets -vserver vs1 -failover-group clyde -targets xena1:e0c, xena1:e0d-100, xena2:a0a