Skip to main content

storage firmware shelf show

Contributors
Suggest changes

Display the list of shelf firmware files on the given node

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The storage firmware shelf show command displays the shelf firmware files present on each node.

Parameters

{ [-fields <fieldname>,…​]

If you specify the -fields <fieldname>, …​ parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.

| [-instance ] }

If you specify the -instance parameter, the command displays detailed information about all fields.

[-node {<nodename>|local}] - Node

Selects the files that match the specified node name.

[-filename <text>] - Storage Firmware File

Selects the files that match the specified filename.

Examples

The following example displays the shelf firmware files on each node:

cluster1::> storage firmware shelf show
Node: Node1
Shelf Firmware Files
                  ----------------------------------------
                  AT-FCX.3800.SFW
                  AT-FCX.3800.SFW.FVF
                  ESH4.1400.SFW
                  ESH4.1400.SFW.FVF
Node: Node2
Shelf Firmware Files
                  ----------------------------------------
                  AT-FCX.3800.SFW
                  AT-FCX.3800.SFW.FVF
                  ESH4.1400.SFW
                  ESH4.1400.SFW.FVF
                  8 entries were displayed.