storage firmware shelf show
Display the list of shelf firmware files on the given node
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage firmware shelf show command displays the shelf firmware files present on each node.
Parameters
- {
[-fields <fieldname>,…] -
If you specify the
-fields <fieldname>, …parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]} -
If you specify the
-instanceparameter, the command displays detailed information about all fields. [-node {<nodename>|local}]- Node-
Selects the files that match the specified node name.
[-filename <text>]- Storage Firmware File-
Selects the files that match the specified filename.
Examples
The following example displays the shelf firmware files on each node:
cluster1::> storage firmware shelf show
Node: Node1
Shelf Firmware Files
----------------------------------------
AT-FCX.3800.SFW
AT-FCX.3800.SFW.FVF
ESH4.1400.SFW
ESH4.1400.SFW.FVF
Node: Node2
Shelf Firmware Files
----------------------------------------
AT-FCX.3800.SFW
AT-FCX.3800.SFW.FVF
ESH4.1400.SFW
ESH4.1400.SFW.FVF
8 entries were displayed.