storage disk error show
Display disk component and array LUN configuration errors.
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage disk error show
command displays disk component and array LUN configuration errors.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-uid <text>]
- UID-
Displays the error information of the disk whose unique ID matches the value you specify. A disk unique identifier has the form: `20000000:875D4C32:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000 `
[-array-name <array name>]
- Array Name-
Displays the errors of the storage array whose name you specified.
[-node {<nodename>|local}]
- Controller Name-
Displays the error information for the disks on the clustered node whose name you specified.
[-disk <disk path name>]
- Disk-
Displays detailed error information about the disk you specified.
[-serial-number <text>]
- Serial Number-
Displays the error information for the disk whose serial number you specified.
[-error-id <integer>,…]
- Error ID-
Displays the error information for the disks whose Error IDs match IDs you specified.
[-error-type {onepath|onedomain|control|foreign|toobig|toosmall|invalidblocksize|targetasymmap|deviceassymmap|failovermisconfig|unknown|netapp|fwdownrev|qualfail|diskfail|notallflashdisk}]
- Error Type-
Displays all disk errors of the error types you specified, grouped by type.
-
onepath = The array LUN is accessible only via a single path.
-
onedomain = The array LUN is accessible only via a single fault domain.
-
control = The array LUN cannot be used because it is a control device.
-
foreign = The array LUN is marked as foreign and has some external SCSI reservations other than those from ONTAP.
-
toobig = The array LUN exceeds the maximum array LUN size that ONTAP supports.
-
toosmall = The array LUN is less than the minimum array LUN size that ONTAP supports.
-
invalidblocksize = The array LUN is not a valid block size.
-
targetasymmap = The array LUN is presented more than once on a single target port.
-
deviceassymmap = The array LUN is presented with multiple IDs.
-
failovermisconfig = The array LUN is configured with inconsistent failover methods.
-
unknown = The array LUN from a storage array that is not supported by this version of ONTAP.
-
netapp = A SAN front-end LUN from one ONTAP system that is presented as external storage to another ONTAP system.
-
fwdownrev = The disk firmware is a down version.
-
qualfail = The disk is not supported.
-
diskfail = The disk is in a failed state.
-
notallflashdisk = The disk does not match the All-Flash Optimized personality of the system.
-
Examples
The following example displays configuration errors seen in the system:
cluster1::> storage disk error show Disk Error Type Error Text ---------------- ----------------- -------------------------------------------- 1.02.0 qualfail This disk failed dynamic disk qualification. Update the Disk Qaulification Package.