storage port show
Show storage port information
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage port show
command displays information about the storage ports in the cluster. If no parameters are specified, the default command displays the following information about the storage ports:
-
Node
-
Port
-
Type
-
Speed
-
State
-
Status
To display detailed profile information about a single storage port, use the -node
and -port
parameters.
Parameters
- {
[-fields <fieldname>,…]
-
Displays the specified fields for all the storage ports, in column style output.
- |
[-errors ]
-
Displays the following error status information about the storage ports which have errors:
-
Error type
-
Error severity
-
Error description
-
- |
[-instance ]
} -
Displays expanded information about all the storage ports in the system. If a storage port is specified, then this parameter displays detailed information for that port only.
[-node {<nodename>|local}]
- Node-
Displays detailed information about the storage ports on the specified node.
[-port <text>]
- Port-
Selects the ports with the specified port name.
[-port-type {Unknown|SAS|FC|ENET}]
- Port Type-
Selects the ports of the specified type.
[-port-speed {0|1|1.5|2|2.5|3|4|5|6|8|10|12|14|16|25|32|40|64|100}]
- Port Speed-
Selects the ports with the specified speed.
[-state {enabled|disabled|enable-pending|disable-pending}]
- Port State-
Selects the ports with the specified state.
[-status {unknown|online|online-degraded|offline|link-down|transient-mode}]
- Port Status-
Selects the ports with the specified operational status.
[-description <text>]
- Description-
Selects the ports with the specified description.
[-firmware-rev <text>]
- Firmware Revision-
Selects the ports with the specified firmware revision.
[-serial-number <text>]
- Serial Number-
Selects the ports with the specified serial number.
[-is-dedicated {true|false}]
- Is Dedicated Storage Port?-
Selects the ports that match the specified value for storage-only ports. This value is always true for FC and SAS ports, as well as for ENET ports that are dedicated to storage.
[-part-number <text>]
- Part Number-
Selects the ports with the specified part number.
[-connection-mode {Unknown|Loop|Point-to-point}]
- Connection Mode-
Selects the ports with the specified connection mode.
[-wwnn <FC WWN>]
- World Wide Node Name-
Selects the ports with the specified World Wide Node Name.
[-wwpn <FC WWN>]
- World Wide Port Name-
Selects the ports with the specified World Wide Port Name.
[-board-name <text>]
- Board Name-
Selects the ports with the specified board name.
[-connector-capabilities <integer>,…]
- Connector Capabilities-
Selects the ports with the specified list of connector capabilities.
[-wwn <FC WWN>]
- Base World Wide Name-
Selects the ports with the specified World Wide Name.
[-mfg-part-number <text>]
- MFG Part Number-
Selects the ports with the specified manufacturer part number.
[-nvdata-rev <text>]
- NVDATA Revision-
Selects the ports with the specified NVDATA revision.
[-date-code <text>]
- Date Code-
Selects the ports with the specified date code.
[-connector-technology {active-copper|passive-copper|optical}]
- Connector Technology-
Selects the ports with the specified connector technology.
[-phy-id <integer>,…]
- Phy ID-
Selects the ports that have phys with the specified phy ID.
[-phy-state {enabled|disabled}]
- Phy State-
Selects the ports that have phys with the specified state.
[-phy-status {unknown|online|offline|speed-negotiation-failed|sata-oob-failed}]
- Phy Status-
Selects the ports that have phys with the specified status.
[-phy-speed {0|1|1.5|2|2.5|3|4|5|6|8|10|12|14|16|25|32|40|64|100}]
- Phy Speed-
Selects the ports that have phys with the specified speed.
[-mac-address <text>]
- MAC Address-
Selects ports that match the specified MAC address.
[-mode {storage|network}]
- Mode-
Selects the ports with the specified mode.
[-vlan-id <integer>]
- VLAN ID-
Selects the ports with the specified VLAN ID.
[-vendor-id <text>]
- (DEPRECATED) Vendor ID-
This parameter has been deprecated and may be removed in a future version of ONTAP. Selects the ports with the specified vendor ID.
[-vendor-part-id <text>]
- (DEPRECATED) Vendor part ID-
This parameter has been deprecated and may be removed in a future version of ONTAP. Selects the ports with the specified vendor part ID.
[-device-type <text>]
- Device type-
Selects ports that match the specified device type.
[-hw-rev <text>]
- Hardware Revision-
Selects the ports with the specified hardware revision.
[-error-type {unknown|online|online-degraded|offline|link-down|transient-mode}]
- Error Type-
Selects the ports with the specified error type.
[-error-severity {unknown|notice|warning|error|critical}]
- Error Severity-
Selects the ports with the specified error severity.
[-error-text <text>]
- Error Text-
Selects the ports with the specified error text.
[-corrective-action <text>]
- Corrective Action-
Selects the ports with the specified corrective action.
[-cable-length <text>]
- Cable Length-
Selects the ports with the specified cable length.
[-cable-identifier <text>]
- Cable Identifier-
Selects the ports with the specified cable identifier.
[-cable-end-id {end_0|end_1}]
- Cable End Identifier-
Selects the ports with the specified cable end identifier.
[-connector-type {QSFP|QSFP+|QSFP28|Mini-SAS HD|SFP}]
- Connector Type-
Selects the ports with the specified connector type.
[-connector-vendor <text>]
- Connector Vendor-
Selects the ports with the specified connector vendor.
[-connector-part-number <text>]
- Connector Part Number-
Selects the ports with the specified connector part number.
[-connector-serial-number <text>]
- Connector Serial Number-
Selects the ports with the specified connector serial number.
[-is-redundant {true|false}]
- Is Redundant?-
Selects the ports that are redundant (true) or not redundant (false). A port is redundant if all attached devices have a second path through another port.
[-in-use {true|false}]
- In Use?-
Selects the ports that are in use (true) or not in use (false). A port is in use if any devices are connected using this port.
Examples
The following example displays information about all storage ports in the cluster:
cluster1::> storage port show Speed VLAN Node Port Type Mode (Gb/s) State Status ID -------------- ---- ----- ------- ------ -------- --------- ---- cluster1-01 4a SAS - 0 enabled offline - 4b SAS - 0 enabled offline - 4c SAS - 0 enabled offline - 4d SAS - 0 enabled offline - e3a ENET network - - - - e3b ENET storage 100 enabled online 30 e5a ENET storage 100 enabled online 30 e5b ENET network - - - - cluster1-02 4a SAS - 0 enabled offline - 4b SAS - 0 enabled offline - 4c SAS - 0 enabled offline - 4d SAS - 0 enabled offline - e3a ENET network - - - - e3b ENET storage 100 enabled online 30 e5a ENET storage 100 enabled online 30 e5b ENET network - - - - 16 entries were displayed.
The following example displays detailed information about port e5a on node node1:
cluster1::> storage port show -node cluster1-01 -port e5a Node: cluster1-01 Port: e5a Port Type: ENET Mode: storage Description: 40G/100G Ethernet Controller CX5 Firmware Revision: 16.23.1020 MAC Address: ec:0d:9a:65:e4:44 Is Dedicated: false Serial Number: MT1730X00227 Connector Vendor: Molex Inc. Connector Part Number: 112-00322 Connector Serial Number: 532120266 Port Speed: 100 Gb/s Port State: enabled Port Status: online