storage port show
Show storage port information
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage port show
command displays information about the storage ports in the cluster. If no parameters are specified, the default command displays the following information about the storage ports:
-
Node
-
Port
-
Type
-
Speed
-
State
-
Status
To display detailed profile information about a single storage port, use the -node
and -port
parameters.
Parameters
- {
[-fields <fieldname>,…]
-
Displays the specified fields for all the storage ports, in column style output.
- |
[-errors ]
-
Displays the following error status information about the storage ports which have errors:
-
Error type
-
Error severity
-
Error description
-
- |
[-instance ]
} -
Displays expanded information about all the storage ports in the system. If a storage port is specified, then this parameter displays detailed information for that port only.
[-node {<nodename>|local}]
- Node-
Displays detailed information about the storage ports on the specified node.
[-port <text>]
- Port-
Selects the ports with the specified port name.
[-port-type {Unknown|SAS|FC}]
- Port Type-
Selects the ports of the specified type.
[-port-speed {0|1|1.5|2|3|4|6|8|10|12|16|32}]
- Port Speed-
Selects the ports with the specified speed.
[-state {enabled|disabled}]
- Port State-
Selects the ports with the specified state.
[-status {unknown|online|online-degraded|offline|link-down}]
- Port Status-
Selects the ports with the specified operational status.
[-description <text>]
- Description-
Selects the ports with the specified description.
[-firmware-rev <text>]
- Firmware Revision-
Selects the ports with the specified firmware revision.
[-serial-number <text>]
- Serial Number-
Selects the ports with the specified serial number.
[-connection-mode {Unknown|Loop|Point-to-point}]
- Connection Mode-
Selects the ports with the specified connection mode.
[-wwnn <FC WWN>]
- World Wide Node Name-
Selects the ports with the specified World Wide Node Name.
[-wwpn <FC WWN>]
- World Wide Port Name-
Selects the ports with the specified World Wide Port Name.
[-board-name <text>]
- Board Name-
Selects the ports with the specified board name.
[-connector-capabilities <integer>,…]
- Connector Capabilities-
Selects the ports with the specified list of connector capabilities.
[-wwn <FC WWN>]
- Base World Wide Name-
Selects the ports with the specified World Wide Name.
[-mfg-part-number <text>]
- MFG Part Number-
Selects the ports with the specified manufacturer part number.
[-nvdata-rev <text>]
- NVDATA Revision-
Selects the ports with the specified NVDATA revision.
[-part-number <text>]
- Part Number-
Selects the ports with the specified part number.
[-date-code <text>]
- Date Code-
Selects the ports with the specified date code.
[-cable-length <text>]
- Cable Length-
Selects the ports with the specified cable length.
[-cable-identifier <text>]
- Cable Identifier-
Selects the ports with the specified cable identifier.
[-cable-end-id {end_0|end_1}]
- Cable End Identifier-
Selects the ports with the specified cable end identifier.
[-connector-technology {active-copper|passive-copper|optical}]
- Connector Technology-
Selects the ports with the specified connector technology.
[-phy-id <integer>,…]
- Phy ID-
Selects the ports that have phys with the specified phy ID.
[-phy-state {enabled|disabled}]
- Phy State-
Selects the ports that have phys with the specified state.
[-phy-status {unknown|online|offline|speed-negotiation-failed|sata-oob-failed}]
- Phy Status-
Selects the ports that have phys with the specified status.
[-phy-speed {0|1|1.5|2|3|4|6|8|10|12|16|32}]
- Phy Speed-
Selects the ports that have phys with the specified speed.
[-error-type {unknown|online|online-degraded|offline|link-down}]
- Error Type-
Selects the ports with the specified error type.
[-error-severity {unknown|notice|warning|error|critical}]
- Error Severity-
Selects the ports with the specified error severity.
[-error-text <text>]
- Error Text-
Selects the ports with the specified error text.
[-corrective-action <text>]
- Corrective Action-
Selects the ports with the specified corrective action.
[-connector-type {QSFP|QSFP+|Mini-SAS HD|SFP}]
- Connector Type-
Selects the ports with the specified connector type.
[-connector-vendor <text>]
- Connector Vendor-
Selects the ports with the specified connector vendor.
[-connector-part-number <text>]
- Connector Part Number-
Selects the ports with the specified connector part number.
[-connector-serial-number <text>]
- Connector Serial Number-
Selects the ports with the specified connector serial number.
Examples
The following example displays information about all storage ports in the cluster:
cluster1::> storage port show Speed Node Port Type (Gb/s) State Status ------------------ ---- ---- ------ -------- --------------- node1 0a SAS 0 disabled offline 0b SAS 6 enabled online 1a FC 0 disabled offline 1b FC 2 enabled online node2 0a SAS 6 enabled online 0b SAS 6 enabled online-degraded 1a FC 2 enabled online 1b FC 2 enabled online
The following example displays detailed information about port 0a on node node1:
cluster1::> storage port show -node node1 -port 0b Node: node1 Port: 0b Description: SAS Host Adapter 0b (PMC-Sierra PM8001 rev. C) Firmware Revision: 01.12.06.00 Base WWN: 50:0a:09:80:00:82:47:b4 Connector Type: qsfp Connector Vendor: Molex Inc. Connector Part Number: 112-00177+A0 Connector Technology: passive_copper Connector Serial Number: 017920547 Cable Length: 2m Cable End Identifier: end_1 Cable Identifier: 500a09800082847f-500a0980008247b4 Port Speed: 6 Gb/s Port State: enabled Port Status: online Phy State: [0] enabled, online, 6 Gb/s [1] enabled, online, 6 Gb/s [2] enabled, online, 6 Gb/s [3] enabled, online, 6 Gb/s