lun copy modify
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Modify an ongoing LUN copy operation
Availability: This command is available to cluster and Vserver administrators at the admin privilege level.
Description
The lun copy modify
command modifies the maximum throughput of an ongoing copy operation.
LUNs cannot be copied to or from a Vserver with Infinite Volume. |
Parameters
- {
-vserver <Vserver Name>
- Vserver Name -
Specifies the name of the Vserver that will host the destination LUN.
-destination-path <path>
- Destination Path-
Specifies the full path to the new LUN, in the format /vol/<volume>[/<qtree>]/<lun>.
-max-throughput {<integer>[KB|MB|GB|TB|PB]}
- Maximum Transfer Rate (per sec)-
Specifies the maximum amount of data, in bytes, that can be transferred per second in support of this operation. This mechanism can be used to throttle a transfer, to reduce its impact on the performance of the source and destination nodes.
The specified value will be rounded up to the nearest megabyte.
Examples
cluster1::> lun copy modify -vserver vs1 -destination-path /vol/vol2/lun2 -max-throughput 25MB
Modifies the maximum throughput for the ongoing copy job identified by Vserver vs1
and destination path /vol/vol2/lun2
to 25 MB/sec.