fci.link.break
- Severity
-
ERROR
- Description
-
This message occurs when the Fibre Channel adapter detects a break in the link.
- Corrective Action
-
If the adapter is in use, check the cabling.
- Syslog Message
-
Link break detected on Fibre Channel adapter %s.
- Parameters
-
adapterName (STRING): Name of the associated Fibre Channel host bus adapter.
fci.link.break.shelf.fw.update
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the Fibre Channel adapter detects a break in the link due to a shelf firmware update being performed.
- Corrective Action
-
No corrective action is required. This is expected behavior when firmware is being downloaded to a shelf.
- Syslog Message
-
Link break detected on Fibre Channel adapter %s while downloading shelf firmware.
- Parameters
-
adapterName (STRING): Name of the associated Fibre Channel host bus adapter.
fci.link.error
- Severity
-
ERROR
- Description
-
This message occurs when the Fibre Channel adapter cannot recover the link and the link is going offline.
- Corrective Action
-
If the adapter is in use, check the Fibre Channel cabling. If this does not resolve the issue, contact NetApp technical support.
- Syslog Message
-
Could not recover link on Fibre Channel adapter %s after %d seconds. Taking the adapter offline.
- Parameters
-
adapterName (STRING): Name of the associated Fibre Channel host bus adapter.
downTime (INT): Amount of time that the link was down.