A newer release of this product is available.
        
        
      fcvi.cross events
fcvi.cross.connect.detected
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when the fcvi driver detects a cross connection
 - Corrective Action
 - 
Check the FCVI interconnect cabling at the local and remote nodes. FCVI adapter ports fcvi_device_0s and fcvi_device_1s should not be connected to the same fabric. Contact NetApp technical support if the problem persists.
 - Syslog Message
 - 
FC-VI adapter: Cross Connection detected between local port %s and remote port %s. Local System ID = %llu, Remote System ID = %llu.
 - Parameters
 - 
lname (STRING): Local node's port name.
rname (STRING): Remote node's port name.
lsid (LONGINT): Local node's system id.
rsid (LONGINT): Remote node's system id.