A newer release of this product is available.
fcvi.cross events
Contributors
Suggest changes
fcvi.cross.connect.detected
- Severity
-
ERROR
- Description
-
This message occurs when the fcvi driver detects a cross connection
- Corrective Action
-
Check the FCVI interconnect cabling at the local and remote nodes. FCVI adapter ports fcvi_device_0s and fcvi_device_1s should not be connected to the same fabric. Contact NetApp technical support if the problem persists.
- Syslog Message
-
FC-VI adapter: Cross Connection detected between local port %s and remote port %s. Local System ID = %llu, Remote System ID = %llu.
- Parameters
-
lname (STRING): Local node's port name.
rname (STRING): Remote node's port name.
lsid (LONGINT): Local node's system id.
rsid (LONGINT): Remote node's system id.