nvmeof.hostport events
Collection of separate PDF docs
Creating your file...
nvmeof.hostport.clear
- Severity
-
NOTICE
- Description
-
This message occurs when a node shelf is no longer cabled incorrectly from a port that is not a storage port. Indicates condition has cleared.
- Corrective Action
-
(None).
- Syslog Message
-
Shelf on node %s with SN %s is no longer cabled incorrectly from a port that is not a storage port.
- Parameters
-
node_name (STRING): Host name connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.
nvmeof.hostport.error
- Severity
-
ERROR
- Description
-
This message occurs when the host port is incorrectly cabled to the shelf.
- Corrective Action
-
Reconnect the host port to a Storage Ethernet port.
- Syslog Message
-
Port %s is not configured as a Storage Ethernet port on node %s. It is incorrectly cabled to Shelf with SN %s.
- Parameters
-
host_port (STRING): Host port connected to the cable.
node_name (STRING): Host name connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.