      adt.wrkrq events
adt.wrkrq.init.fail
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when an internal audit worker queue fails to initialize.
 - Corrective Action
 - 
Available system resources are required for this feature to function. The Audit subsystem might not function, or might function with reduced performance. The best way to accomplish that is through a system reboot. For HA configurations, operational disruption can be minimized by initiating a partner takeover followed by a reboot of this partner. After the reboot is complete,issue a "giveback" command to return services to this partner.
 - Syslog Message
 - 
Audit subsystem internal error: Audit worker queue failed to initialize; system reboot might be required.
 - Parameters
 - 
(None).