pha.dev events
pha.dev.get.capacity.failed
- Severity
-
ERROR
- Description
-
This message occurs when ONTAP®software fails to get a drives's capacity after an extended wait. As a result, cannot add the drive.
- Corrective Action
-
Ensure that the hypervisor's device is still connected and accessible by ONTAP.
- Syslog Message
-
Failed to get drive capacity for device %s%d after %d seconds.
- Parameters
-
devname (STRING): Name of the device.
unit (INT): Unit number of the device.
wait_time (INT): Number of seconds waited for capacity information.
pha.dev.get.uuid.bioReadErr
- Severity
-
ERROR
- Description
-
This message occurs when block read operation for the passthrough host adapter (PHA) disk header returns an error. As a result, Data ONTAP® is unable to add or manage this device.
- Corrective Action
-
Ensure that the device is still connected to and accessible by Data ONTAP® and retry the operation.
- Syslog Message
-
Failed to get UUID for device %s%d. Reason: Block read operation returned an error: 0x%x.
- Parameters
-
devname (STRING): Name of the device.
unit (INT): Unit number of the device.
bio_error (INTHEX): Error code returned by block read operation.
pha.dev.get.uuid.devNotAdded
- Severity
-
ERROR
- Description
-
This message occurs when Data ONTAP® fails to get disk header after multiple retries and finally give up. As a result, Data ONTAP® is unable to add the disk.
- Corrective Action
-
Ensure that the device is still connected to and accessible by Data ONTAP® and retry the operation.
- Syslog Message
-
Failed to get disk header for device %s%d. Number of bioerr %d Retries %d.
- Parameters
-
devname (STRING): Name of the device.
unit (INT): Unit number of the device.
bioerr_cnt (INT): Number of BIO errors.
retry_cnt (INT): Number of retries.
pha.dev.get.uuid.devNotExist
- Severity
-
ERROR
- Description
-
This message occurs when Data ONTAP® fails to retrieve the the descriptor for the passthrough host adapter (PHA) device. As a result, Data ONTAP® fails to read the header on this device and is unable to add or manage it.
- Corrective Action
-
Ensure that the device is still connected to and accessible by Data ONTAP® and retry the operation.
- Syslog Message
-
Failed to retrieve the descriptor for device %s%d. Reason: %s.
- Parameters
-
devname (STRING): Name of the device.
unit (INT): Unit number of the device.
error (STRING): Error message.
pha.dev.uuidWriteHeaderErr
- Severity
-
ERROR
- Description
-
This message occurs when Data ONTAP® fails to write the header to the passthrough host adapter (PHA) device. As a result, Data ONTAP® is unable to add or manage this device.
- Corrective Action
-
Ensure that the device is still connected to and accessible by Data ONTAP® and retry the operation.
- Syslog Message
-
Failed to write header to the device %s%d.
- Parameters
-
devname (STRING): Name of the device.
unit (INT): Unit number of the device.