vifmgr.hv events
vifmgr.hv.nohostconfig
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when no Hypervisor host configuration is available. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
 - Corrective Action
 - 
Verify the Hypervisor host configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
 - Syslog Message
 - 
The %s health monitor cannot access the Hypervisor host configuration.
 - Parameters
 - 
monitor (STRING): Health monitor name.
 
vifmgr.hv.nosnmpconfig
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when no Hypervisor SNMP configuration is available. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
 - Corrective Action
 - 
Verify the Hypervisor SNMP configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
 - Syslog Message
 - 
The %s health monitor cannot access the required Hypervisor SNMP configuration.
 - Parameters
 - 
monitor (STRING): Health monitor name.
 
vifmgr.hv.nouplinkmapping
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when no Hypervisor uplink mapping is available for the specified port. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
 - Corrective Action
 - 
Verify the Hypervisor uplink mapping configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
 - Syslog Message
 - 
The %s health monitor cannot access the Hypervisor uplink mapping configuration for node %s port %s.
 - Parameters
 - 
monitor (STRING): Health monitor name.
node (STRING): Name of the node.
port (STRING): Name of the port. 
vifmgr.hv.nouplinkstatus
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when there is an error obtaining the Hypervisor uplink status for the specified port.
 - Corrective Action
 - 
Verify the Hypervisor's host and SNMP configuration.
 - Syslog Message
 - 
Unable to obtain the hypervisor uplink status for port %s with hypervisor uplinks %s.
 - Parameters
 - 
port (STRING): Name of the port.