vifmgr.hv events
vifmgr.hv.nohostconfig
- Severity
-
ALERT
- Description
-
This message occurs when no Hypervisor host configuration is available. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
- Corrective Action
-
Verify the Hypervisor host configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
- Syslog Message
-
The %s health monitor cannot access the Hypervisor host configuration.
- Parameters
-
monitor (STRING): Health monitor name.
vifmgr.hv.nosnmpconfig
- Severity
-
ALERT
- Description
-
This message occurs when no Hypervisor SNMP configuration is available. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
- Corrective Action
-
Verify the Hypervisor SNMP configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
- Syslog Message
-
The %s health monitor cannot access the required Hypervisor SNMP configuration.
- Parameters
-
monitor (STRING): Health monitor name.
vifmgr.hv.nouplinkmapping
- Severity
-
ALERT
- Description
-
This message occurs when no Hypervisor uplink mapping is available for the specified port. This is required by ONTAP® software to monitor the health of the hypervisor uplinks.
- Corrective Action
-
Verify the Hypervisor uplink mapping configuration. Without it, ONTAP cannot monitor the health of the hypervisor uplinks, preventing data LIFs from failing over if the uplink were to go down.
- Syslog Message
-
The %s health monitor cannot access the Hypervisor uplink mapping configuration for node %s port %s.
- Parameters
-
monitor (STRING): Health monitor name.
node (STRING): Name of the node.
port (STRING): Name of the port.
vifmgr.hv.nouplinkstatus
- Severity
-
ERROR
- Description
-
This message occurs when there is an error obtaining the Hypervisor uplink status for the specified port.
- Corrective Action
-
Verify the Hypervisor's host and SNMP configuration.
- Syslog Message
-
Unable to obtain the hypervisor uplink status for port %s with hypervisor uplinks %s.
- Parameters
-
port (STRING): Name of the port.
uplinks (STRING): List of hypervisor uplinks associated with the port.