sp.eth events
Collection of separate PDF docs
Creating your file...
sp.eth.switch.upd.failed
- Severity
-
ERROR
- Description
-
This message occurs when Service Processor (SP) or Baseboard Management Controller (BMC) fails to auto-update the internal Ethernet switch.
- Corrective Action
-
-
Perform a manual Ethernet Switch update from SP or BMC CLI. 2. If the failures persist, contact NetApp technical support.
-
- Syslog Message
-
%s Ethernet switch auto-update failed.
- Parameters
-
sp_type (STRING): SP type
sp.eth.switch.upd.start
- Severity
-
NOTICE
- Description
-
This message occurs when the Service Processor (SP) or Baseboard Management Controller (BMC) starts an internal Ethernet switch auto-update. During the Ethernet switch update, SP or BMC and e0M network connections might be temporarily affected.
- Corrective Action
-
(None).
- Syslog Message
-
%s is starting Ethernet switch auto-update %s.
- Parameters
-
sp_type (STRING): SP type
switch_ver (STRING): Current and bundled switch version.
sp.eth.switch.upd.success
- Severity
-
NOTICE
- Description
-
This message occurs when the Service Processor (SP) or Baseboard Management Controller (BMC) completes an internal Ethernet switch auto-update.
- Corrective Action
-
(None).
- Syslog Message
-
%s Ethernet switch version updated %s.
- Parameters
-
sp_type (STRING): SP type