sp.eth events
sp.eth.switch.upd.failed
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when Service Processor (SP) or Baseboard Management Controller (BMC) fails to auto-update the internal Ethernet switch.
 - Corrective Action
 - 
- 
Perform a manual Ethernet Switch update from SP or BMC CLI. 2. If the failures persist, contact NetApp technical support.
 
 - 
 - Syslog Message
 - 
%s Ethernet switch auto-update failed.
 - Parameters
 - 
sp_type (STRING): SP type
 
sp.eth.switch.upd.start
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the Service Processor (SP) or Baseboard Management Controller (BMC) starts an internal Ethernet switch auto-update. During the Ethernet switch update, SP or BMC and e0M network connections might be temporarily affected.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
%s is starting Ethernet switch auto-update %s.
 - Parameters
 - 
sp_type (STRING): SP type
switch_ver (STRING): Current and bundled switch version. 
sp.eth.switch.upd.success
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the Service Processor (SP) or Baseboard Management Controller (BMC) completes an internal Ethernet switch auto-update.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
%s Ethernet switch version updated %s.
 - Parameters
 - 
sp_type (STRING): SP type
switch_ver (STRING): Previous and updated switch version.