config.bridge events
Collection of separate PDF docs
Creating your file...
config.bridge.adapter.invalid
- Severity
-
ERROR
- Description
-
This message occurs when an FC-to-SAS bridge is attached to an unsupported FC adapter port. Only QLogic® 4-Gb/s or 8-Gb/s adapters are supported.
- Corrective Action
-
Attach the FC-to-SAS bridge to a supported FC adapter port on the controller.
- Syslog Message
-
FC-to-SAS bridge %s S/N [%s] is attached to unsupported FC adapter port %s.
- Parameters
-
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge.
adapterName (STRING): Name of the associated FC host bus adapter.
config.bridge.extra.port
- Severity
-
ERROR
- Description
-
This message occurs when both FC ports of an FC-to-SAS bridge are attached to the same controller.
- Corrective Action
-
Follow the defined Fabric or Stretch MetroCluster wiring guide.
- Syslog Message
-
Both FC ports of FC-to-SAS bridge %s S/N [%s] are attached to this controller.
- Parameters
-
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge.
config.bridge.fw.mismatch
- Severity
-
ERROR
- Description
-
This message occurs when two or more attached FC-to-SAS bridges are running different firmware revisions.
- Corrective Action
-
For more information about downloading and installing updated firmware, check your support provider's web site or knowledgebase.
- Syslog Message
-
Two or more %s FC-to-SAS bridges are running different firmware revisions.
- Parameters
-
bridgeModel (STRING): Name of the FC-to-SAS bridge model.
config.bridge.SAS.miswired
- Severity
-
ERROR
- Description
-
This message occurs when the SAS disk shelves behind an FC-to-SAS bridge are not wired in the correct order.
- Corrective Action
-
Follow the defined Fabric or Stretch MetroCluster wiring guide.
- Syslog Message
-
The SAS disk shelves behind FC-to-SAS bridge %s S/N [%s] are not correctly wired.
- Parameters
-
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge.
config.bridge.SAS2Domain
- Severity
-
ERROR
- Description
-
This message occurs when a disk is multipathed to one SAS domain; that is, both ports of the disk are visible from the same bridge FC port.
- Corrective Action
-
Recable the disk shelf containing the specified disk, so that the two disk ports are in different SAS domains.
- Syslog Message
-
Disk %s is multipathed to the same SAS domain. The two disk ports must be in different SAS domains.
- Parameters
-
disk (STRING): Name of the disk.
config.bridge.unsupp.shelf
- Severity
-
ALERT
- Description
-
This message occurs when an FC-to-SAS bridge discovers a disk shelf that it does not support.
- Corrective Action
-
Verify the bridge firmware is up-to-date with minimum FW rev required for support of this shelf type. If the bridge firmware supports the disk shelf but the error condition persists, remove the disk shelf.
- Syslog Message
-
FC-to-SAS %s bridge with S/N: %s WWN: %s has unsupported %s shelf type attached.
- Parameters
-
bridgeType (STRING): Type of FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the bridge.
bridgeWWN (STRING): World Wide Name of the bridge.
shelfType (STRING): Type of shelf.