config.bridge events
config.bridge.adapter.invalid
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when an FC-to-SAS bridge is attached to an unsupported FC adapter port. Only QLogic® 4-Gb/s or 8-Gb/s adapters are supported.
 - Corrective Action
 - 
Attach the FC-to-SAS bridge to a supported FC adapter port on the controller.
 - Syslog Message
 - 
FC-to-SAS bridge %s S/N [%s] is attached to unsupported FC adapter port %s.
 - Parameters
 - 
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge.
adapterName (STRING): Name of the associated FC host bus adapter. 
config.bridge.extra.port
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when both FC ports of an FC-to-SAS bridge are attached to the same controller.
 - Corrective Action
 - 
Follow the defined Fabric or Stretch MetroCluster wiring guide.
 - Syslog Message
 - 
Both FC ports of FC-to-SAS bridge %s S/N [%s] are attached to this controller.
 - Parameters
 - 
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge. 
config.bridge.fw.mismatch
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when two or more attached FC-to-SAS bridges are running different firmware revisions.
 - Corrective Action
 - 
For more information about downloading and installing updated firmware, check your support provider's web site or knowledgebase.
 - Syslog Message
 - 
Two or more %s FC-to-SAS bridges are running different firmware revisions.
 - Parameters
 - 
bridgeModel (STRING): Name of the FC-to-SAS bridge model.
 
config.bridge.SAS.miswired
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when the SAS disk shelves behind an FC-to-SAS bridge are not wired in the correct order.
 - Corrective Action
 - 
Follow the defined Fabric or Stretch MetroCluster wiring guide.
 - Syslog Message
 - 
The SAS disk shelves behind FC-to-SAS bridge %s S/N [%s] are not correctly wired.
 - Parameters
 - 
bridgeName (STRING): Name of the FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the FC-to-SAS bridge. 
config.bridge.SAS2Domain
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when a disk is multipathed to one SAS domain; that is, both ports of the disk are visible from the same bridge FC port.
 - Corrective Action
 - 
Recable the disk shelf containing the specified disk, so that the two disk ports are in different SAS domains.
 - Syslog Message
 - 
Disk %s is multipathed to the same SAS domain. The two disk ports must be in different SAS domains.
 - Parameters
 - 
disk (STRING): Name of the disk.
 
config.bridge.unsupp.shelf
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when an FC-to-SAS bridge discovers a disk shelf that it does not support.
 - Corrective Action
 - 
Verify the bridge firmware is up-to-date with minimum FW rev required for support of this shelf type. If the bridge firmware supports the disk shelf but the error condition persists, remove the disk shelf.
 - Syslog Message
 - 
FC-to-SAS %s bridge with S/N: %s WWN: %s has unsupported %s shelf type attached.
 - Parameters
 - 
bridgeType (STRING): Type of FC-to-SAS bridge.
bridgeSerialNum (STRING): Serial number of the bridge.
bridgeWWN (STRING): World Wide Name of the bridge.
shelfType (STRING): Type of shelf.