A newer release of this product is available.
        
        
      san.mccpurgeverifyfailed events
san.MCCPurgeVerifyFailed
- Severity
 - 
ERROR
 - Description
 - 
This message occurs in MetroCluster™ configurations on clustered Data ONTAP® systems when a SAN cache purge verify operation fails. The corresponding Vservers are not available to take part in the subsequent switchover or switchback operation until the purge verify operation succeeds.
 - Corrective Action
 - 
Contact NetApp technical support for assistance in purging the SAN cache.
 - Syslog Message
 - 
The following Vservers: %s failed in the SAN cache purge verify operation. Contact NetApp technical support for assistance in purging the SAN cache.
 - Parameters
 - 
vserver (STRING): List of Vservers that failed the purge verify operation.