A newer release of this product is available.
        
        
      ses.mismatch events
ses.mismatch.fw.version
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when the two disk shelf modules within the same disk shelf are running different versions of the firmware.
 - Corrective Action
 - 
Download the latest disk shelf firmware to the disk shelf module that is not up-to-date.
 - Syslog Message
 - 
The disk shelf modules on disk shelf %s.%d are running two different firmware versions. Disk shelf module A is running %s, and disk shelf module B is running %s.
 - Parameters
 - 
channelName (STRING): Name of the adapter port or switch port.
shelfID (INT): ID of the disk shelf.
revision_str (STRING): Revision number for disk shelf module A, the top disk shelf module.
revision_str2 (STRING): Revision number for disk shelf module B, the bottom disk shelf module.