monitor.iocard events
monitor.ioCard.degraded
- Severity
-
ALERT
- Description
-
This message indicates that an I/O card is degraded.
- Corrective Action
-
Exchange or replace the card with a known good card in the same I/O slot. If the problem persists, contact NetApp technical support for replacement assistance.
- Syslog Message
-
IO card is degraded: %s
- Parameters
-
reasonText (STRING): Slot number of the card and the reason the card is degraded.
monitor.ioCard.ok
- Severity
-
NOTICE
- Description
-
This message indicates that an I/O card is operating properly.
- Corrective Action
-
None.
- Syslog Message
-
IO card on slot %d is OK
- Parameters
-
slot_number (INT): Slot number of the card.
monitor.ioCard.sfp.noTemp
- Severity
-
ERROR
- Description
-
This message occurs when an optical transceiver or cable connected to the I/O module does not report an internal temperature reading. The transceiver or cable might not include a temperature sensor or the sensor is not currently readable. The system's environmental policy will not be able to regulate cooling for this hardware component via system fan speed changes.
- Corrective Action
-
If possible, exchange or replace the transceiver with one that includes a temperature sensor.
- Syslog Message
-
Optical transceiver or cable does not support an internal temperature sensor. Sensor: %s.
- Parameters
-
sensor (STRING): Sensor ID of the optical transceiver.
monitor.ioCard.temp.timeout
- Severity
-
ERROR
- Description
-
This message occurs when a timeout occurs while reading the temperature of an I/O card. I/O card temperature-based policies are temporarily disabled. Normal operation will resume once the reading of I/O card temperatures is successful.
- Corrective Action
-
Contact NetApp technical support.
- Syslog Message
-
Timeout while reading temperature of I/O card in slot %d.
- Parameters
-
slot (INT): Slot Number of the I/O card.