Skip to main content
ONTAP EMS reference

monitor.iocard events

Suggest changes

monitor.ioCard.degraded

Severity

ALERT

Description

This message indicates that an I/O card is degraded.

Corrective Action

Exchange or replace the card with a known good card in the same I/O slot. If the problem persists, contact NetApp technical support for replacement assistance.

Syslog Message

IO card is degraded: %s

Parameters

reasonText (STRING): Slot number of the card and the reason the card is degraded.

monitor.ioCard.ok

Severity

NOTICE

Description

This message indicates that an I/O card is operating properly.

Corrective Action

None.

Syslog Message

IO card on slot %d is OK

Parameters

slot_number (INT): Slot number of the card.

monitor.ioCard.sfp.noTemp

Severity

ERROR

Description

This message occurs when an optical transceiver or cable connected to the I/O module does not report an internal temperature reading. The transceiver or cable might not include a temperature sensor or the sensor is not currently readable. The system's environmental policy will not be able to regulate cooling for this hardware component via system fan speed changes.

Corrective Action

If possible, exchange or replace the transceiver with one that includes a temperature sensor.

Syslog Message

Optical transceiver or cable does not support an internal temperature sensor. Sensor: %s.

Parameters

sensor (STRING): Sensor ID of the optical transceiver.

monitor.ioCard.temp.timeout

Severity

ERROR

Description

This message occurs when a timeout occurs while reading the temperature of an I/O card. I/O card temperature-based policies are temporarily disabled. Normal operation will resume once the reading of I/O card temperatures is successful.

Corrective Action

Contact NetApp technical support.

Syslog Message

Timeout while reading temperature of I/O card in slot %d.

Parameters