Verifying that the back-end configuration matches the intended configuration
After resolving the back-end configuration errors detected by storage errors show
, you must check whether the existing back-end configuration matches the configuration you intended, and fix issues arising out of any mismatch.
-
Enter the following command:
storage array config show
The
storage array config show
output groups information about LUN groups, LUN counts, and paths by storage array, as the following example for an HA pair shows:mysystem1::> storage array config show LUN LUN Node Group Count Array Name Array Target Port Initiator ------------ ----- ----- --------------- ------------------ --------- mysystem1a 0 10 DGC_RAID5_1 5005076303030124 1a 5005076303088124 1b 5005076303130124 1c 5005076303188124 1d mysystem1b 0 10 DGC_RAID5_1 5005076303030124 1a 5005076303088124 1b 5005076303130124 1c 5005076303188124 1d 8 entries were displayed.
-
Check the
storage array config show
output for each problem statement in the following table, and refer to the appropriate information for solution.If you find this problem… See this information… Empty LUN groups
Missing expected storage arrays
More array LUN groups than expected
Fewer array LUN groups than expected
Array LUN groups do not show the number of LUNs expected
Fewer paths than expected
More paths than expected