Skip to main content
A newer release of this product is available.

Create an NVMe service

Contributors

POST /protocols/nvme/services

Creates an NVMe service.

Required properties

  • svm.uuid or svm.name - The existing SVM in which to create the NVMe service.

  • vserver nvme create

Request Body

Name Type Description

_links

_links

enabled

boolean

The administrative state of the NVMe service. The NVMe service can be disabled to block all NVMe connectivity to the SVM.

This is optional in POST and PATCH. The default setting is true (enabled) in POST.

svm

svm

SVM, applies only to SVM-scoped objects.

Example request
{
  "_links": {
    "self": {
      "href": "/api/resourcelink"
    }
  },
  "svm": {
    "_links": {
      "self": {
        "href": "/api/resourcelink"
      }
    },
    "name": "svm1",
    "uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
  }
}

Response

Status: 201, Created
Name Type Description

_links

_links

num_records

integer

Number of records.

records

array[nvme_service]

Example response
{
  "_links": {
    "next": {
      "href": "/api/resourcelink"
    },
    "self": {
      "href": "/api/resourcelink"
    }
  },
  "records": {
    "_links": {
      "self": {
        "href": "/api/resourcelink"
      }
    },
    "svm": {
      "_links": {
        "self": {
          "href": "/api/resourcelink"
        }
      },
      "name": "svm1",
      "uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
    }
  }
}

Error

Status: Default

ONTAP Error Response Codes

Error Code Description

1115127

The cluster lacks a valid NVMe license.

2621462

The supplied SVM does not exist.

2621507

NVMe is not allowed for the specified SVM.

2621706

The specified svm.uuid and svm.name do not refer to the same SVM.

2621707

No SVM was specified. Either svm.name or svm.uuid must be supplied.

72089650

An NVMe service already exists for the specified SVM.

5374893

The SVM is stopped. The SVM must be running to create an NVMe service.

72089900

An NVMe service cannot be creating in an SVM that is configured for a SAN protocol.

Name Type Description

error

error

Example error
{
  "error": {
    "arguments": {
      "code": "string",
      "message": "string"
    },
    "code": "4",
    "message": "entry doesn't exist",
    "target": "uuid"
  }
}

Definitions

See Definitions

href

Name Type Description

href

string

Name Type Description

self

href

svm

SVM, applies only to SVM-scoped objects.

Name Type Description

_links

_links

name

string

The name of the SVM.

uuid

string

The unique identifier of the SVM.

nvme_service

A Non-Volatile Memory Express (NVMe) service defines the properties of the NVMe controller target for an SVM. There can be at most one NVMe service for an SVM. An SVM's NVMe service must be created before NVMe host initiators can connect to the SVM.

An NVMe service is identified by the UUID of its SVM.

Name Type Description

_links

_links

enabled

boolean

The administrative state of the NVMe service. The NVMe service can be disabled to block all NVMe connectivity to the SVM.

This is optional in POST and PATCH. The default setting is true (enabled) in POST.

svm

svm

SVM, applies only to SVM-scoped objects.

Name Type Description

next

href

self

href

error_arguments

Name Type Description

code

string

Argument code

message

string

Message argument

error

Name Type Description

arguments

array[error_arguments]

Message arguments

code

string

Error code

message

string

Error message

target

string

The target parameter that caused the error.