Use CentOS 7.9 with ONTAP
You can use the ONTAP SAN host configuration settings to configure CentOS 7.9 with ONTAP as the target.
Install the Linux Unified Host Utilities
The NetApp Linux Unified Host Utilities software package is available on the NetApp Support Site in a 32-bit and 64-bit .rpm file. If you do not know which file is right for your configuration, use the NetApp Interoperability Matrix Tool to verify which one you need.
NetApp strongly recommends installing the Linux Unified Host Utilities, but it is not mandatory. The utilities do not change any settings on your Linux host. The utilities improve management and assist NetApp customer support in gathering information about your configuration.
If you have a version of Linux Unified Host Utilities currently installed, you should either upgrade it, or remove it and follow these steps to install the latest version.
-
Download the 32-bit or 64-bit Linux Unified Host Utilities software package from the NetApp Support Site Site to your host.
-
Use the following command to install the software package:
rpm -ivh netapp_linux_unified_host_utilities-7-1.x86_64
You can use the configuration settings provided in this document to configure cloud clients connected to Cloud Volumes ONTAP and Amazon FSx for ONTAP. |
SAN Toolkit
The toolkit is installed automatically when you install the NetApp Host Utilities package. This kit provides the sanlun
utility, which helps you manage LUNs and HBAs. The sanlun
command returns information about the LUNs mapped to your host, multipathing, and information necessary to create initiator groups.
In the following example, the sanlun lun show
command returns LUN information.
# sanlun lun show all
Example output:
controller(7mode/E-Series)/ device host lun vserver(cDOT/FlashRay) lun-pathname filename adapter protocol size Product ------------------------------------------------------------------------------------ data_vserver /vol/vol1/lun1 /dev/sdb host16 FCP 120.0g cDOT data_vserver /vol/vol1/lun1 /dev/sdc host15 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sdd host16 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sde host15 FCP 120.0g cDOT
SAN Booting
If you decide to use SAN booting, it must be supported by your configuration. You can use the NetApp Interoperability Matrix Tool to verify that your OS, HBA, HBA firmware and the HBA boot BIOS, and ONTAP version are supported.
-
Map the SAN boot LUN to the host.
-
Verify that multiple paths are available.
Multiple paths become available after the host OS is up and running on the paths. -
Enable SAN booting in the server BIOS for the ports to which the SAN boot LUN is mapped.
For information on how to enable the HBA BIOS, see your vendor-specific documentation.
-
Reboot the host to verify that the boot was successful.
Multipathing
For CentOS 7.9 the /etc/multipath.conf file must exist, but you do not need to make specific changes to the file. CentOS 7.9 is compiled with all settings required to recognize and correctly manage ONTAP LUNs.
You can use the multipath -ll
command to verify the settings for your ONTAP LUNs.
The following sections provide example multipath outputs for a LUN mapped to ASA and non-ASA personas.
All SAN Array configurations
In All SAN Array (ASA) configurations, all paths to a given LUN are active and optimized. This improves performance by serving I/O operations through all paths at the same time.
The following example displays the correct output for an ONTAP LUN:
# multipath -ll 3600a09803831347657244e527766394e dm-5 NETAPP,LUN C-Mode size=80G features='4 queue_if_no_path pg_init_retries 50 retain_attached_hw_handle' hwhandler='1 alua' wp=rw `-+- policy='service-time 0' prio=50 status=active |- 11:0:7:1 sdfi 130:64 active ready running |- 11:0:9:1 sdiy 8:288 active ready running |- 11:0:10:1 sdml 69:464 active ready running |- 11:0:11:1 sdpt 131:304 active ready running
A single LUN shouldn't require more than four paths. More than eight paths might cause path issues during storage failures. |
Non-ASA configurations
For non-ASA configurations, there should be two groups of paths with different priorities. The paths with higher priorities are Active/Optimized, meaning they are serviced by the controller where the aggregate is located. The paths with lower priorities are active but are non-optimized because they are served from a different controller. The non-optimized paths are only used when optimized paths are not available.
The following example displays the correct output for an ONTAP LUN with two Active/Optimized paths and two Active/Non-Optimized paths:
# multipath -ll 3600a09803831347657244e527766394e dm-5 NETAPP,LUN C-Mode size=80G features='4 queue_if_no_path pg_init_retries 50 retain_attached_hw_handle' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | |- 11:0:1:0 sdj 8:144 active ready running | |- 11:0:2:0 sdr 65:16 active ready running `-+- policy='service-time 0' prio=10 status=enabled |- 11:0:0:0 sdb 8:i6 active ready running |- 12:0:0:0 sdz 65:144 active ready running
A single LUN shouldn't require more than four paths. More than eight paths might cause path issues during storage failures. |
Recommended Settings
The CentOS 7.9 OS is compiled to recognize ONTAP LUNs and automatically set all configuration parameters correctly for both ASA and non-ASA configuration.
The multipath.conf
file must exist for the multipath daemon to start. If this file does not exist, you can create an empty, zero-byte file by using the following command:
touch /etc/multipath.conf
The first time you create the multipath.conf
file, you might need to enable and start the multipath services by using the following commands:
# chkconfig multipathd on # /etc/init.d/multipathd start
There is no requirement to add anything directly to the multipath.conf
file unless you have devices that you don't want multipath to manage or you have existing settings that override defaults. To exclude unwanted devices, add the following syntax to the multipath.conf
file, replacing <DevId> with the WWID string of the device you want to exclude:
blacklist { wwid <DevId> devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
The following example determines the WWID of a device and adds it to the multipath.conf
file.
-
Determine the WWID:
# /lib/udev/scsi_id -gud /dev/sda 360030057024d0730239134810c0cb833
sda
is the local SCSI disk that you want to add to the blacklist. -
Add the
WWID
to the blacklist stanza in/etc/multipath.conf
:blacklist { wwid 360030057024d0730239134810c0cb833 devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
You should always check your /etc/multipath.conf
file for legacy settings, especially in the defaults section, that might be overriding the default settings.
The following table demonstrates the critical multipathd
parameters for ONTAP LUNs and the required values. If a host is connected to LUNs from other vendors and any of these parameters are overridden, they must be corrected by later stanzas in the multipath.conf
file that apply specifically to ONTAP LUNs. Without this correction, the ONTAP LUNs might not work as expected. You should only override these defaults in consultation with NetApp, the OS vendor, or both, and only when the impact is fully understood.
Parameter | Setting |
---|---|
detect_prio |
yes |
dev_loss_tmo |
"infinity" |
failback |
immediate |
fast_io_fail_tmo |
5 |
features |
"3 queue_if_no_path pg_init_retries 50" |
flush_on_last_del |
"yes" |
hardware_handler |
"0" |
no_path_retry |
queue |
path_checker |
"tur" |
path_grouping_policy |
"group_by_prio" |
path_selector |
"service-time 0" |
polling_interval |
5 |
prio |
"ontap" |
product |
LUN.* |
retain_attached_hw_handler |
yes |
rr_weight |
"uniform" |
user_friendly_names |
no |
vendor |
NETAPP |
The following example shows how to correct an overridden default. In this case, the multipath.conf
file defines values for path_checker
and no_path_retry
that are not compatible with ONTAP LUNs. If they cannot be removed because of other SAN arrays still attached to the host, these parameters can be corrected specifically for ONTAP LUNs with a device stanza.
defaults { path_checker readsector0 no_path_retry fail } devices { device { vendor "NETAPP " product "LUN.*" no_path_retry queue path_checker tur } }
KVM settings
You can use the recommended settings to configure Kernel-based Virtual Machine (KVM) as well. There are no changes required to configure KVM as the LUN is mapped to the hypervisor.
Known issues
The CentOS 7.9 with ONTAP release has the following known issues:
NetApp Bug ID | Title | Description |
---|---|---|
1440718 |
If you unmap or map a LUN without performing a SCSI rescan, it might lead to data corruption on the host. |
When you set the 'disable_changed_wwids' multipath configuration parameter to YES, it disables access to the path device in the event of a WWID change. Multipath will disable access to the path device until the WWID of the path is restored to the WWID of the multipath device. To learn more, see NetApp Knowledge Base: The filesystem corruption on iSCSI LUN on the Oracle Linux 7. |