Skip to main content
Cluster and storage switches

Install the Reference Configuration File (RCF) script

Contributors netapp-yvonneo

Follow this procedure to install the RCF script.

What you'll need

Before installing the RCF script, make sure that the following are available on the switch:

  • Cumulus Linux is installed. See the Hardware Universe for supported versions.

  • IP address, subnet mask, and default gateway defined via DHCP or manually configured.

Note You must specify a user in the RCF (in addition to the admin user) to be used specifically for log collection.
Current RCF script versions

There are two RCF scripts available for Cluster and Storage applications. Download RCFs from here. The procedure for each is the same.

  • Cluster: MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP

  • Storage: MSN2100-RCF-v1.x-Storage

About the examples

The following example procedure shows how to download and apply the RCF script for Cluster switches.

Example command output uses switch management IP address 10.233.204.71, netmask 255.255.254.0 and default gateway 10.233.204.1.

Example 1. Steps
Cumulus Linux 4.4.3
  1. Display the available interfaces on the SN2100 switch:

    admin@sw1:mgmt:~$ net show interface all
    
    State  Name   Spd  MTU    Mode         LLDP                Summary
    -----  -----  ---  -----  -----------  ------------------  --------------
    ...
    ...
    ADMDN  swp1   N/A  9216   NotConfigured
    ADMDN  swp2   N/A  9216   NotConfigured
    ADMDN  swp3   N/A  9216   NotConfigured
    ADMDN  swp4   N/A  9216   NotConfigured
    ADMDN  swp5   N/A  9216   NotConfigured
    ADMDN  swp6   N/A  9216   NotConfigured
    ADMDN  swp7   N/A  9216   NotConfigured
    ADMDN  swp8   N/A  9216   NotConfigured
    ADMDN  swp9   N/A  9216   NotConfigured
    ADMDN  swp10  N/A  9216   NotConfigured
    ADMDN  swp11  N/A  9216   NotConfigured
    ADMDN  swp12  N/A  9216   NotConfigured
    ADMDN  swp13  N/A  9216   NotConfigured
    ADMDN  swp14  N/A  9216   NotConfigured
    ADMDN  swp15  N/A  9216   NotConfigured
    ADMDN  swp16  N/A  9216   NotConfigured
  2. Copy the RCF python script to the switch.

    admin@sw1:mgmt:~$ pwd
    /home/cumulus
    cumulus@cumulus:mgmt: /tmp$ scp <user>@<host:/<path>/MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP ./
    ssologin@10.233.204.71's password:
    MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP         100% 8607   111.2KB/s         00:00
    Note While scp is used in the example, you can use your preferred method of file transfer.
  3. Apply the RCF python script MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP.

    cumulus@cumulus:mgmt:/tmp$ sudo python3 MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP
    [sudo] password for cumulus:
    ...
    Step 1: Creating the banner file
    Step 2: Registering banner message
    Step 3: Updating the MOTD file
    Step 4: Ensuring passwordless use of cl-support command by admin
    Step 5: Disabling apt-get
    Step 6: Creating the interfaces
    Step 7: Adding the interface config
    Step 8: Disabling cdp
    Step 9: Adding the lldp config
    Step 10: Adding the RoCE base config
    Step 11: Modifying RoCE Config
    Step 12: Configure SNMP
    Step 13: Reboot the switch

    The RCF script completes the steps listed in the example above.

    Note In step 3 Updating the MOTD file above, the command cat /etc/motd is run. This allows you to verify the RCF filename, RCF version, ports to use, and other important information in the RCF banner.
    Note For any RCF python script issues that cannot be corrected, contact NetApp Support for assistance.
  4. Verify the configuration after the reboot:

    admin@sw1:mgmt:~$ net show interface all
    
    State  Name      Spd   MTU    Mode       LLDP              Summary
    -----  --------- ----  -----  ---------- ----------------- --------
    ...
    ...
    DN     swp1s0    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp1s1    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp1s2    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp1s3    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp2s0    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp2s1    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp2s2    N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp2s3    N/A   9216   Trunk/L2                     Master: bridge(UP)
    UP     swp3      100G  9216   Trunk/L2                     Master: bridge(UP)
    UP     swp4      100G  9216   Trunk/L2                     Master: bridge(UP)
    DN     swp5      N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp6      N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp7      N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp8      N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp9      N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp10     N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp11     N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp12     N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp13     N/A   9216   Trunk/L2                     Master: bridge(UP)
    DN     swp14     N/A   9216   Trunk/L2                     Master: bridge(UP)
    UP     swp15     N/A   9216   BondMember                   Master: bond_15_16(UP)
    UP     swp16     N/A   9216   BondMember                   Master: bond_15_16(UP)
    ...
    ...
    
    admin@sw1:mgmt:~$ net show roce config
    RoCE mode.......... lossless
    Congestion Control:
      Enabled SPs.... 0 2 5
      Mode........... ECN
      Min Threshold.. 150 KB
      Max Threshold.. 1500 KB
    PFC:
      Status......... enabled
      Enabled SPs.... 2 5
      Interfaces......... swp10-16,swp1s0-3,swp2s0-3,swp3-9
    
    DSCP                     802.1p  switch-priority
    -----------------------  ------  ---------------
    0 1 2 3 4 5 6 7               0                0
    8 9 10 11 12 13 14 15         1                1
    16 17 18 19 20 21 22 23       2                2
    24 25 26 27 28 29 30 31       3                3
    32 33 34 35 36 37 38 39       4                4
    40 41 42 43 44 45 46 47       5                5
    48 49 50 51 52 53 54 55       6                6
    56 57 58 59 60 61 62 63       7                7
    
    switch-priority  TC  ETS
    ---------------  --  --------
    0 1 3 4 6 7       0  DWRR 28%
    2                 2  DWRR 28%
    5                 5  DWRR 43%
  5. Verify information for the transceiver in the interface:

    admin@sw1:mgmt:~$ net show interface pluggables
    Interface  Identifier     Vendor Name  Vendor PN        Vendor SN       Vendor Rev
    ---------  -------------  -----------  ---------------  --------------  ----------
    swp3       0x11 (QSFP28)  Amphenol     112-00574        APF20379253516  B0
    swp4       0x11 (QSFP28)  AVAGO        332-00440        AF1815GU05Z     A0
    swp15      0x11 (QSFP28)  Amphenol     112-00573        APF21109348001  B0
    swp16      0x11 (QSFP28)  Amphenol     112-00573        APF21109347895  B0
  6. Verify that the nodes each have a connection to each switch:

    admin@sw1:mgmt:~$ net show lldp
    
    LocalPort  Speed  Mode        RemoteHost              RemotePort
    ---------  -----  ----------  ----------------------  -----------
    swp3       100G   Trunk/L2    sw1                     e3a
    swp4       100G   Trunk/L2    sw2                     e3b
    swp15      100G   BondMember  sw13                    swp15
    swp16      100G   BondMember  sw14                    swp16
  7. Verify the health of cluster ports on the cluster.

    1. Verify that e0d ports are up and healthy across all nodes in the cluster:

      cluster1::*> network port show -role cluster
      
      Node: node1
                                                                             Ignore
                                                        Speed(Mbps) Health   Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
      --------- ------------ ---------------- ---- ---- ----------- -------- ------
      e3a       Cluster      Cluster          up   9000  auto/10000 healthy  false
      e3b       Cluster      Cluster          up   9000  auto/10000 healthy  false
      
      Node: node2
                                                                             Ignore
                                                        Speed(Mbps) Health   Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
      --------- ------------ ---------------- ---- ---- ----------- -------- ------
      e3a       Cluster      Cluster          up   9000  auto/10000 healthy  false
      e3b       Cluster      Cluster          up   9000  auto/10000 healthy  false
    2. Verify the switch health from the cluster (this might not show switch sw2, since LIFs are not homed on e0d).

      cluster1::*> network device-discovery show -protocol lldp
      Node/       Local  Discovered
      Protocol    Port   Device (LLDP: ChassisID)  Interface Platform
      ----------- ------ ------------------------- --------- ----------
      node1/lldp
                  e3a    sw1 (b8:ce:f6:19:1a:7e)   swp3      -
                  e3b    sw2 (b8:ce:f6:19:1b:96)   swp3      -
      
      node2/lldp
                  e3a    sw1 (b8:ce:f6:19:1a:7e)   swp4      -
                  e3b    sw2 (b8:ce:f6:19:1b:96)   swp4      -
      
      
      cluster1::*> system switch ethernet show -is-monitoring-enabled-operational true
      Switch                      Type               Address          Model
      --------------------------- ------------------ ---------------- -----
      sw1                         cluster-network    10.233.205.90    MSN2100-CB2RC
           Serial Number: MNXXXXXXGD
            Is Monitored: true
                  Reason: None
        Software Version: Cumulus Linux version 4.4.3 running on Mellanox
                          Technologies Ltd. MSN2100
          Version Source: LLDP
      
      sw2                         cluster-network    10.233.205.91    MSN2100-CB2RC
           Serial Number: MNCXXXXXXGS
            Is Monitored: true
                  Reason: None
        Software Version: Cumulus Linux version 4.4.3 running on Mellanox
                          Technologies Ltd. MSN2100
          Version Source: LLDP
Cumulus Linux 5.x
  1. Display the available interfaces on the SN2100 switch:

    admin@sw1:mgmt:~$ nv show interface
    Interface     MTU   Speed State Remote Host         Remote Port- Type      Summary
    ------------- ----- ----- ----- ------------------- ------------ --------- -------------
    + cluster_isl 9216  200G  up                                      bond
    + eth0        1500  100M  up    mgmt-sw1            Eth105/1/14   eth       IP Address: 10.231.80 206/22
      eth0                                                                      IP Address: fd20:8b1e:f6ff:fe31:4a0e/64
    + lo          65536       up                                      loopback  IP Address: 127.0.0.1/8
      lo                                                                        IP Address: ::1/128
    + swp1s0      9216 10G    up cluster01                e0b         swp
    .
    .
    .
    + swp15      9216 100G    up sw2                      swp15       swp
    + swp16      9216 100G    up sw2                      swp16       swp
  2. Copy the RCF python script to the switch.

    admin@sw1:mgmt:~$ pwd
    /home/cumulus
    cumulus@cumulus:mgmt: /tmp$ scp <user>@<host:/<path>/MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP ./
    ssologin@10.233.204.71's password:
    MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP          100% 8607   111.2KB/s         00:00
    Note While scp is used in the example, you can use your preferred method of file transfer.
  3. Apply the RCF python script MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP.

    cumulus@cumulus:mgmt:/tmp$ sudo python3 MSN2100-RCF-v1.x-Cluster-HA-Breakout-LLDP
    [sudo] password for cumulus:
    .
    .
    Step 1: Creating the banner file
    Step 2: Registering banner message
    Step 3: Updating the MOTD file
    Step 4: Ensuring passwordless use of cl-support command by admin
    Step 5: Disabling apt-get
    Step 6: Creating the interfaces
    Step 7: Adding the interface config
    Step 8: Disabling cdp
    Step 9: Adding the lldp config
    Step 10: Adding the RoCE base config
    Step 11: Modifying RoCE Config
    Step 12: Configure SNMP
    Step 13: Reboot the switch

    The RCF script completes the steps listed in the example above.

    Note In step 3 Updating the MOTD file above, the command cat /etc/issue is run. This allows you to verify the RCF filename, RCF version, ports to use, and other important information in the RCF banner.

    For example:

    admin@sw1:mgmt:~$ cat /etc/issue
    ******************************************************************************
    *
    * NetApp Reference Configuration File (RCF)
    * Switch       : Mellanox MSN2100
    * Filename     : MSN2100-RCF-1.x-Cluster-HA-Breakout-LLDP
    * Release Date : 13-02-2023
    * Version      : 1.x-Cluster-HA-Breakout-LLDP
    *
    * Port Usage:
    * Port 1      : 4x10G Breakout mode for Cluster+HA Ports, swp1s0-3
    * Port 2      : 4x25G Breakout mode for Cluster+HA Ports, swp2s0-3
    * Ports 3-14  : 40/100G for Cluster+HA Ports, swp3-14
    * Ports 15-16 : 100G Cluster ISL Ports, swp15-16
    *
    * NOTE:
    *   RCF manually sets swp1s0-3 link speed to 10000 and
    *   auto-negotiation to off for Intel 10G
    *   RCF manually sets swp2s0-3 link speed to 25000 and
    *   auto-negotiation to off for Chelsio 25G
    *
    *
    * IMPORTANT: Perform the following steps to ensure proper RCF installation:
    * - Copy the RCF file to /tmp
    * - Ensure the file has execute permission
    * - From /tmp run the file as sudo python3 <filename>
    *
    ******************************************************************************
    Note For any RCF python script issues that cannot be corrected, contact NetApp Support for assistance.
  4. Verify the configuration after the reboot:

    admin@sw1:mgmt:~$ nv show interface
    Interface   MTU   Speed State Remote Host Remote Port Type Summary
    ----------- ----- ----- ----- ----------- ----------- ---- -------------
    + cluster_isl 9216 200G up bond
    + eth0 1500 100M up RTP-LF01-410G38.rtp.eng.netapp.com Eth105/1/14 eth IP Address: 10.231.80.206/22
    eth0 IP Address: fd20:8b1e:b255:85a0:bace:f6ff:fe31:4a0e/64
    + lo 65536 up loopback IP Address: 127.0.0.1/8
    lo IP Address: ::1/128
    + swp1s0 9216 10G up cumulus1 e0b swp
    .
    .
    .
    + swp15 9216 100G up cumulus swp15 swp
    
    admin@sw1:mgmt:~$ nv show interface
    Interface     MTU   Speed State Remote Host         Remote Port- Type      Summary
    ------------- ----- ----- ----- ------------------- ------------ --------- -------------
    + cluster_isl 9216  200G  up                                      bond
    + eth0        1500  100M  up    mgmt-sw1            Eth105/1/14   eth       IP Address: 10.231.80 206/22
      eth0                                                                      IP Address: fd20:8b1e:f6ff:fe31:4a0e/64
    + lo          65536       up                                      loopback  IP Address: 127.0.0.1/8
      lo                                                                        IP Address: ::1/128
    + swp1s0      9216 10G    up cluster01                e0b         swp
    .
    .
    .
    + swp15      9216 100G    up sw2                      swp15       swp
    + swp16      9216 100G    up sw2                      swp16       swp
    
    admin@sw1:mgmt:~$ nv show qos roce
                       operational  applied   description
    -----------------  -----------  --------- ----------------------------------------
    enable             on                     Turn feature 'on' or 'off'. This feature is disabled by default.
    mode               lossless     lossless  Roce Mode
    congestion-control
      congestion-mode   ECN,RED                Congestion config mode
      enabled-tc        0,2,5                  Congestion config enabled Traffic Class
      max-threshold     195.31 KB              Congestion config max-threshold
      min-threshold     39.06 KB               Congestion config min-threshold
      probability       100
    lldp-app-tlv
      priority          3                      switch-priority of roce
      protocol-id       4791                   L4 port number
      selector          UDP                    L4 protocol
    pfc
      pfc-priority      2, 5                   switch-prio on which PFC is enabled
      rx-enabled        enabled                PFC Rx Enabled status
      tx-enabled        enabled                PFC Tx Enabled status
    trust
      trust-mode        pcp,dscp               Trust Setting on the port for packet classification
    
    RoCE PCP/DSCP->SP mapping configurations
    ===========================================
            pcp  dscp                     switch-prio
        --  ---  -----------------------  -----------
        0   0    0,1,2,3,4,5,6,7          0
        1   1    8,9,10,11,12,13,14,15    1
        2   2    16,17,18,19,20,21,22,23  2
        3   3    24,25,26,27,28,29,30,31  3
        4   4    32,33,34,35,36,37,38,39  4
        5   5    40,41,42,43,44,45,46,47  5
        6   6    48,49,50,51,52,53,54,55  6
        7   7    56,57,58,59,60,61,62,63  7
    
    RoCE SP->TC mapping and ETS configurations
    =============================================
            switch-prio  traffic-class  scheduler-weight
        --  -----------  -------------  ----------------
        0   0            0              DWRR-28%
        1   1            0              DWRR-28%
        2   2            2              DWRR-28%
        3   3            0              DWRR-28%
        4   4            0              DWRR-28%
        5   5            5              DWRR-43%
        6   6            0              DWRR-28%
        7   7            0              DWRR-28%
    
    RoCE pool config
    ===================
            name                   mode     size  switch-priorities  traffic-class
        --  ---------------------  -------  ----  -----------------  -------------
        0   lossy-default-ingress  Dynamic  50%   0,1,3,4,6,7        -
        1   roce-reserved-ingress  Dynamic  50%   2,5                -
        2   lossy-default-egress   Dynamic  50%   -                  0
        3   roce-reserved-egress   Dynamic  inf   -                  2,5
    
    Exception List
    =================
            description
        --  -----------------------------------------------------------------------…
        1   RoCE PFC Priority Mismatch.Expected pfc-priority: 3.
        2   Congestion Config TC Mismatch.Expected enabled-tc: 0,3.
        3   Congestion Config mode Mismatch.Expected congestion-mode: ECN.
        4   Congestion Config min-threshold Mismatch.Expected min-threshold: 150000.
        5   Congestion Config max-threshold Mismatch.Expected max-threshold:
            1500000.
        6   Scheduler config mismatch for traffic-class mapped to switch-prio0.
            Expected scheduler-weight: DWRR-50%.
        7   Scheduler config mismatch for traffic-class mapped to switch-prio1.
            Expected scheduler-weight: DWRR-50%.
        8   Scheduler config mismatch for traffic-class mapped to switch-prio2.
            Expected scheduler-weight: DWRR-50%.
        9   Scheduler config mismatch for traffic-class mapped to switch-prio3.
            Expected scheduler-weight: DWRR-50%.
        10  Scheduler config mismatch for traffic-class mapped to switch-prio4.
            Expected scheduler-weight: DWRR-50%.
        11  Scheduler config mismatch for traffic-class mapped to switch-prio5.
            Expected scheduler-weight: DWRR-50%.
        12  Scheduler config mismatch for traffic-class mapped to switch-prio6.
            Expected scheduler-weight: strict-priority.
        13  Scheduler config mismatch for traffic-class mapped to switch-prio7.
            Expected scheduler-weight: DWRR-50%.
        14  Invalid reserved config for ePort.TC[2].Expected 0 Got 1024
        15  Invalid reserved config for ePort.TC[5].Expected 0 Got 1024
        16  Invalid traffic-class mapping for switch-priority 2.Expected 0 Got 2
        17  Invalid traffic-class mapping for switch-priority 3.Expected 3 Got 0
        18  Invalid traffic-class mapping for switch-priority 5.Expected 0 Got 5
        19  Invalid traffic-class mapping for switch-priority 6.Expected 6 Got 0
    Incomplete Command: set interface swp3-16 link fast-linkupp3-16 link fast-linkup
    Incomplete Command: set interface swp3-16 link fast-linkupp3-16 link fast-linkup
    Incomplete Command: set interface swp3-16 link fast-linkupp3-16 link fast-linkup
    Note The exceptions listed do not affect performance and can be safely ignored.
  5. Verify information for the transceiver in the interface:

    admin@sw1:mgmt:~$ nv show interface --view=pluggables
    Interface  Identifier     Vendor Name  Vendor PN        Vendor SN       Vendor Rev
    ---------  -------------  -----------  ---------------  --------------  ----------
    swp1s0     0x00 None
    swp1s1     0x00 None
    swp1s2     0x00 None
    swp1s3     0x00 None
    swp2s0     0x11 (QSFP28)  CISCO-LEONI  L45593-D278-D20  LCC2321GTTJ     00
    swp2s1     0x11 (QSFP28)  CISCO-LEONI  L45593-D278-D20  LCC2321GTTJ     00
    swp2s2     0x11 (QSFP28)  CISCO-LEONI  L45593-D278-D20  LCC2321GTTJ     00
    swp2s3     0x11 (QSFP28)  CISCO-LEONI  L45593-D278-D20  LCC2321GTTJ     00
    swp3       0x00 None
    swp4       0x00 None
    swp5       0x00 None
    swp6       0x00 None
    .
    .
    .
    swp15      0x11 (QSFP28)  Amphenol     112-00595        APF20279210117  B0
    swp16      0x11 (QSFP28)  Amphenol     112-00595        APF20279210166  B0
  6. Verify that the nodes each have a connection to each switch:

    admin@sw1:mgmt:~$ nv show interface --view=lldp
    
    LocalPort  Speed  Mode        RemoteHost               RemotePort
    ---------  -----  ----------  -----------------------  -----------
    eth0       100M   Mgmt        mgmt-sw1                 Eth110/1/29
    swp2s1     25G    Trunk/L2    node1                    e0a
    swp15      100G   BondMember  sw2                      swp15
    swp16      100G   BondMember  sw2                      swp16
  7. Verify the health of cluster ports on the cluster.

    1. Verify that e0d ports are up and healthy across all nodes in the cluster:

      cluster1::*> network port show -role cluster
      
      Node: node1
                                                                             Ignore
                                                        Speed(Mbps) Health   Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
      --------- ------------ ---------------- ---- ---- ----------- -------- ------
      e3a       Cluster      Cluster          up   9000  auto/10000 healthy  false
      e3b       Cluster      Cluster          up   9000  auto/10000 healthy  false
      
      Node: node2
                                                                             Ignore
                                                        Speed(Mbps) Health   Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status   Status
      --------- ------------ ---------------- ---- ---- ----------- -------- ------
      e3a       Cluster      Cluster          up   9000  auto/10000 healthy  false
      e3b       Cluster      Cluster          up   9000  auto/10000 healthy  false
    2. Verify the switch health from the cluster (this might not show switch sw2, since LIFs are not homed on e0d).

      cluster1::*> network device-discovery show -protocol lldp
      Node/       Local  Discovered
      Protocol    Port   Device (LLDP: ChassisID)  Interface Platform
      ----------- ------ ------------------------- --------- ----------
      node1/lldp
                  e3a    sw1 (b8:ce:f6:19:1a:7e)   swp3      -
                  e3b    sw2 (b8:ce:f6:19:1b:96)   swp3      -
      
      node2/lldp
                  e3a    sw1 (b8:ce:f6:19:1a:7e)   swp4      -
                  e3b    sw2 (b8:ce:f6:19:1b:96)   swp4      -
      
      
      cluster1::*> system switch ethernet show -is-monitoring-enabled-operational true
      Switch                      Type               Address          Model
      --------------------------- ------------------ ---------------- -----
      sw1                         cluster-network    10.233.205.90    MSN2100-CB2RC
           Serial Number: MNXXXXXXGD
            Is Monitored: true
                  Reason: None
        Software Version: Cumulus Linux version 5.4.0 running on Mellanox
                          Technologies Ltd. MSN2100
          Version Source: LLDP
      
      sw2                         cluster-network    10.233.205.91    MSN2100-CB2RC
           Serial Number: MNCXXXXXXGS
            Is Monitored: true
                  Reason: None
        Software Version: Cumulus Linux version 5.4.0 running on Mellanox
                          Technologies Ltd. MSN2100
          Version Source: LLDP