Update an Ethernet switch
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
PATCH /network/ethernet/switches/{name}
Introduced In: 9.8
Update Ethernet Switch REST API
Parameters
Name | Type | In | Required | Description |
---|---|---|---|---|
name |
string |
path |
True |
Switch Name |
return_timeout |
integer |
query |
False |
The number of seconds to allow the call to execute before returning. When doing a POST, PATCH, or DELETE operation on a single record, the default is 0 seconds. This means that if an asynchronous operation is started, the server immediately returns HTTP code 202 (Accepted) along with a link to the job. If a non-zero value is specified for POST, PATCH, or DELETE operations, ONTAP waits that length of time to see if the job completes so it can return something other than 202.
|
Request Body
Name | Type | Description |
---|---|---|
_links |
||
address |
string |
IP Address. |
discovered |
boolean |
Discovered By ONTAP CDP/LLDP
|
model |
string |
Model Number. |
monitoring |
||
name |
string |
Name. |
network |
string |
Switch Network. |
serial_number |
string |
Serial Number. |
snmp |
||
version |
string |
Software Version. |
Example request
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"address": "string",
"model": "string",
"monitoring": {
"reason": "string"
},
"name": "string",
"network": "string",
"serial_number": "string",
"snmp": {
"user": "string",
"version": "string"
},
"version": "string"
}
Response
Status: 202, Accepted
Name | Type | Description |
---|---|---|
job |
Example response
{
"job": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"uuid": "string"
}
}
Error
Status: Default
ONTAP Error Response Codes
Error Code | Description |
---|---|
12517378 |
Settings updated, but the IP address "{address}" is not reachable. Verify that the address is valid or check the network path. |
12517380 |
Settings updated, but the SNMP validation request timed out. Verify that the "snmp.user" parameter is valid. |
12517382 |
Settings updated, but the SNMP validation request timed out. Verify that the "snmp.user" parameter is valid (i.e., the SNMPv3 user exists in ONTAP and on the remote switch). If the "snmp.user" parameter is valid, verify that the SNMPv3 user's credentials are the same both in ONTAP as well as in the remote switch. If a custom engine-id was provided for the SNMPv3 user, ensure it is the same as that of the remote switch. |
Name | Type | Description |
---|---|---|
error |
Example error
{
"error": {
"arguments": [
{
"code": "string",
"message": "string"
}
],
"code": "4",
"message": "entry doesn't exist",
"target": "uuid"
}
}
Definitions
See Definitions
href
Name | Type | Description |
---|---|---|
href |
string |
self_link
Name | Type | Description |
---|---|---|
self |
monitoring
Name | Type | Description |
---|---|---|
enabled |
boolean |
Enable Health Monitoring. |
monitored |
boolean |
Is Monitored. |
reason |
string |
Reason For Not Monitoring. |
snmp
Name | Type | Description |
---|---|---|
user |
string |
Community String or SNMPv3 Username. |
version |
string |
SNMP Version. |
switch
Ethernet Switch REST API
Name | Type | Description |
---|---|---|
_links |
||
address |
string |
IP Address. |
discovered |
boolean |
Discovered By ONTAP CDP/LLDP
|
model |
string |
Model Number. |
monitoring |
||
name |
string |
Name. |
network |
string |
Switch Network. |
serial_number |
string |
Serial Number. |
snmp |
||
version |
string |
Software Version. |
_links
Name | Type | Description |
---|---|---|
self |
job_link
Name | Type | Description |
---|---|---|
_links |
||
uuid |
string |
The UUID of the asynchronous job that is triggered by a POST, PATCH, or DELETE operation. |
error_arguments
Name | Type | Description |
---|---|---|
code |
string |
Argument code |
message |
string |
Message argument |
error
Name | Type | Description |
---|---|---|
arguments |
array[error_arguments] |
Message arguments |
code |
string |
Error code |
message |
string |
Error message |
target |
string |
The target parameter that caused the error. |