Skip to main content
A newer release of this product is available.

Create an EBR policy for an SVM

Contributors

POST /storage/snaplock/event-retention/policies

Introduced In: 9.7

Creates an Event Based Retention (EBR) policy for an SVM. The input parameter retention_period expects the duration in ISO 8601 format or infinite.

Required properties

  • name - Event retention policy name.

  • retention_period - Retention period of the EBR policy.

  • snaplock event-retention policy create

Parameters

Name Type In Required Description

return_records

boolean

query

False

The default is false. If set to true, the records are returned.

  • Default value:

Request Body

Name Type Description

_links

_links

name

string

Specifies the EBR policy name

retention_period

string

Specifies the retention period of an event based retention policy. The retention period value represents a duration and must be specified in the ISO-8601 duration format. The retention period can be in years, months, days, hours or minutes. A period specified for years, months and days is represented in the ISO-8601 format as "PY", "PM", "PD" respectively. For example "P10Y" represents a duration of 10 years. Similarly, a duration in hours, minutes is represented by "PTH", "PTM" respectively. The period string must contain only a single time element i.e. either years, months, days, hours or minutes. A duration which combines different periods is not supported, example "P1Y10M" is not supported. Apart from the duration specified in the ISO-8601 format, the retention period field also accepts the strings "infinite" and "unspecified".

svm

svm

Example request
{
  "_links": {
    "self": {
      "href": "/api/resourcelink"
    }
  },
  "retention_period": "P30M",
  "svm": {
    "_links": {
      "self": {
        "href": "/api/resourcelink"
      }
    },
    "name": "svm1",
    "uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
  }
}

Response

Status: 201, Created
Name Type Description

_links

_links

name

string

Specifies the EBR policy name

retention_period

string

Specifies the retention period of an event based retention policy. The retention period value represents a duration and must be specified in the ISO-8601 duration format. The retention period can be in years, months, days, hours or minutes. A period specified for years, months and days is represented in the ISO-8601 format as "PY", "PM", "PD" respectively. For example "P10Y" represents a duration of 10 years. Similarly, a duration in hours, minutes is represented by "PTH", "PTM" respectively. The period string must contain only a single time element i.e. either years, months, days, hours or minutes. A duration which combines different periods is not supported, example "P1Y10M" is not supported. Apart from the duration specified in the ISO-8601 format, the retention period field also accepts the strings "infinite" and "unspecified".

svm

svm

Example response
{
  "_links": {
    "self": {
      "href": "/api/resourcelink"
    }
  },
  "retention_period": "P30M",
  "svm": {
    "_links": {
      "self": {
        "href": "/api/resourcelink"
      }
    },
    "name": "svm1",
    "uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
  }
}

Error

Status: Default, Error
Name Type Description

error

error

Example error
{
  "error": {
    "arguments": {
      "code": "string",
      "message": "string"
    },
    "code": "4",
    "message": "entry doesn't exist",
    "target": "uuid"
  }
}

Definitions

See Definitions

href

Name Type Description

href

string

Name Type Description

self

href

svm

Name Type Description

_links

_links

name

string

The name of the SVM.

uuid

string

The unique identifier of the SVM.

snaplock_retention_policy

Name Type Description

_links

_links

name

string

Specifies the EBR policy name

retention_period

string

Specifies the retention period of an event based retention policy. The retention period value represents a duration and must be specified in the ISO-8601 duration format. The retention period can be in years, months, days, hours or minutes. A period specified for years, months and days is represented in the ISO-8601 format as "PY", "PM", "PD" respectively. For example "P10Y" represents a duration of 10 years. Similarly, a duration in hours, minutes is represented by "PTH", "PTM" respectively. The period string must contain only a single time element i.e. either years, months, days, hours or minutes. A duration which combines different periods is not supported, example "P1Y10M" is not supported. Apart from the duration specified in the ISO-8601 format, the retention period field also accepts the strings "infinite" and "unspecified".

svm

svm

error_arguments

Name Type Description

code

string

Argument code

message

string

Message argument

error

Name Type Description

arguments

array[error_arguments]

Message arguments

code

string

Error code

message

string

Error message

target

string

The target parameter that caused the error.