Update an FC interface
PATCH /network/fc/interfaces/{uuid}
Introduced In: 9.6
Updates an FC interface.
Related ONTAP commands
-
network interface modify
Learn more
Parameters
Name | Type | In | Required | Description |
---|---|---|---|---|
uuid |
string |
path |
True |
The unique identifier for the FC interface. |
Request Body
Name | Type | Description |
---|---|---|
_links |
||
comment |
string |
A user configurable comment. Optional in POST; valid in PATCH. To clear a prior comment, set the property to an empty string in PATCH. |
data_protocol |
string |
The data protocol for which the FC interface is configured. Required in POST. |
enabled |
boolean |
The administrative state of the FC interface. The FC interface can be disabled to block all FC communication with the SVM through this interface. Optional in POST and PATCH; defaults to true (enabled) in POST. |
location |
The location of the FC interface is defined by the location of its port. An FC port is identified by its UUID, or a combination of its cluster node name and port name. Either the UUID or the cluster node name and port name are required for POST. To move an interface, supply either the port UUID or the cluster node name and port name in a PATCH.
|
|
metric |
Performance numbers, such as IOPS latency and throughput |
|
name |
string |
The name of the FC interface. Required in POST; optional in PATCH. |
port_address |
string |
The port address of the FC interface. Each FC port in an FC switched fabric has its own unique FC port address for routing purposes. The FC port address is assigned by a switch in the fabric when that port logs in to the fabric. This property refers to the address given by a switch to the FC interface when the SVM performs a port login (PLOGI). This is useful for obtaining statistics and diagnostic information from FC switches. This is a hexadecimal encoded numeric value. |
state |
string |
The current operational state of the FC interface. The state is set to down if the interface is not enabled. If the cluster node hosting the port is down or unavailable, no state value is returned. |
statistics |
These are raw performance numbers, such as IOPS latency and throughput. These numbers are aggregated across all nodes in the cluster and increase with the uptime of the cluster. |
|
svm |
SVM, applies only to SVM-scoped objects. |
|
uuid |
string |
The unique identifier of the FC interface. Required in the URL. |
wwnn |
string |
The world wide node name (WWNN) of the FC interface SVM. The WWNN is generated by ONTAP when Fibre Channel Protocol or the NVMe service is created for the FC interface SVM.
|
wwpn |
string |
The world wide port name (WWPN) of the FC interface. The WWPN is generated by ONTAP when the FC interface is created.
|
Example request
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"comment": "string",
"data_protocol": "string",
"location": {
"home_node": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "node1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"home_port": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "0a",
"node": {
"name": "node1"
},
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"node": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "node1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"port": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "0a",
"node": {
"name": "node1"
},
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
}
},
"metric": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"duration": "PT15S",
"iops": {
"read": 200,
"total": 1000,
"write": 100
},
"latency": {
"read": 200,
"total": 1000,
"write": 100
},
"status": "ok",
"throughput": {
"read": 200,
"total": 1000,
"write": 100
},
"timestamp": "2017-01-25 06:20:13 -0500"
},
"name": "fc_lif1",
"port_address": "5060F",
"state": "string",
"statistics": {
"iops_raw": {
"read": 200,
"total": 1000,
"write": 100
},
"latency_raw": {
"read": 200,
"total": 1000,
"write": 100
},
"status": "ok",
"throughput_raw": {
"read": 200,
"total": 1000,
"write": 100
},
"timestamp": "2017-01-25 06:20:13 -0500"
},
"svm": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "svm1",
"uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
},
"uuid": "bce9827d-4d8f-60af-c771-6e8e9af2c6f0",
"wwnn": "20:00:00:50:56:b4:13:01",
"wwpn": "20:00:00:50:56:b4:13:a8"
}
Response
Status: 200, Ok
Error
Status: Default
ONTAP Error Response Codes
Error Code | Description |
---|---|
1966140 |
An interface with the same name already exists. |
1966217 |
The specified port is not valid on the node provided. |
1966238 |
The node or port of an active SAN data interface cannot be changed. |
1966702 |
The destination node is not healthy. |
5373982 |
An invalid WWN was specified. The length is incorrect. |
5373983 |
An invalid WWN was specified. The format is incorrect. |
5374579 |
The SAN Kernel Agent on the node is unavailable. |
5374870 |
A partial failure occurred; renaming the interface failed. Correct the error and resubmit the request. |
5374871 |
The Fibre Channel port identified by the specified UUID does not refer to the same port as that identified by the specified node name and/or port name. |
5374872 |
If either |
5375057 |
An FC port with the provided UUID does not exist. |
72089674 |
You cannot move a Fibre Channel interface configured for the NVMe over FC data protocol. |
Also see the table of common errors in the Response body overview section of this documentation.
Name | Type | Description |
---|---|---|
error |
Example error
{
"error": {
"arguments": [
{
"code": "string",
"message": "string"
}
],
"code": "4",
"message": "entry doesn't exist",
"target": "uuid"
}
}
Definitions
See Definitions
href
Name | Type | Description |
---|---|---|
href |
string |
_links
Name | Type | Description |
---|---|---|
self |
home_node
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
|
uuid |
string |
node
The node on which the FC port is located.
Name | Type | Description |
---|---|---|
name |
string |
The name of the node on which the FC port is located. |
home_port
An FC port is the physical port of an FC adapter on a cluster node that can be connected to an FC network.
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
The name of the FC port. |
node |
The node on which the FC port is located. |
|
uuid |
string |
The unique identifier of the FC port. |
node
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
|
uuid |
string |
port
An FC port is the physical port of an FC adapter on a cluster node that can be connected to an FC network.
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
The name of the FC port. |
node |
The node on which the FC port is located. |
|
uuid |
string |
The unique identifier of the FC port. |
location
The location of the FC interface is defined by the location of its port. An FC port is identified by its UUID, or a combination of its cluster node name and port name. Either the UUID or the cluster node name and port name are required for POST. To move an interface, supply either the port UUID or the cluster node name and port name in a PATCH.
location.node
and location.port
refer to the current location of the FC interface. This can be different from location.home_node
and location.home_port
in instances where the FC interface has failed over to its HA partner node. The location.node
, location.port
, and location.is_home
properties are not available for interfaces on the inactive side of a MetroCluster relationship.
Name | Type | Description |
---|---|---|
home_node |
||
home_port |
An FC port is the physical port of an FC adapter on a cluster node that can be connected to an FC network. |
|
is_home |
boolean |
Indicates if the FC interface is currently on its home node. |
node |
||
port |
An FC port is the physical port of an FC adapter on a cluster node that can be connected to an FC network. |
iops
The rate of I/O operations observed at the storage object.
Name | Type | Description |
---|---|---|
other |
integer |
Performance metric for other I/O operations. Other I/O operations can be metadata operations, such as directory lookups and so on. |
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
latency
The round trip latency in microseconds observed at the storage object.
Name | Type | Description |
---|---|---|
other |
integer |
Performance metric for other I/O operations. Other I/O operations can be metadata operations, such as directory lookups and so on. |
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
throughput
The rate of throughput bytes per second observed at the storage object.
Name | Type | Description |
---|---|---|
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
metric
Performance numbers, such as IOPS latency and throughput
Name | Type | Description |
---|---|---|
_links |
||
duration |
string |
The duration over which this sample is calculated. The time durations are represented in the ISO-8601 standard format. Samples can be calculated over the following durations: |
iops |
The rate of I/O operations observed at the storage object. |
|
latency |
The round trip latency in microseconds observed at the storage object. |
|
status |
string |
Any errors associated with the sample. For example, if the aggregation of data over multiple nodes fails then any of the partial errors might be returned, "ok" on success, or "error" on any internal uncategorized failure. Whenever a sample collection is missed but done at a later time, it is back filled to the previous 15 second timestamp and tagged with "backfilled_data". "Inconsistent_ delta_time" is encountered when the time between two collections is not the same for all nodes. Therefore, the aggregated value might be over or under inflated. "Negative_delta" is returned when an expected monotonically increasing value has decreased in value. "Inconsistent_old_data" is returned when one or more nodes do not have the latest data. |
throughput |
The rate of throughput bytes per second observed at the storage object. |
|
timestamp |
string |
The timestamp of the performance data. |
iops_raw
The number of I/O operations observed at the storage object. This should be used along with delta time to calculate the rate of I/O operations per unit of time.
Name | Type | Description |
---|---|---|
other |
integer |
Performance metric for other I/O operations. Other I/O operations can be metadata operations, such as directory lookups and so on. |
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
latency_raw
The raw latency in microseconds observed at the storage object. This should be divided by the raw IOPS value to calculate the average latency per I/O operation.
Name | Type | Description |
---|---|---|
other |
integer |
Performance metric for other I/O operations. Other I/O operations can be metadata operations, such as directory lookups and so on. |
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
throughput_raw
Throughput bytes observed at the storage object. This should be used along with delta time to calculate the rate of throughput bytes per unit of time.
Name | Type | Description |
---|---|---|
read |
integer |
Performance metric for read I/O operations. |
total |
integer |
Performance metric aggregated over all types of I/O operations. |
write |
integer |
Peformance metric for write I/O operations. |
statistics
These are raw performance numbers, such as IOPS latency and throughput. These numbers are aggregated across all nodes in the cluster and increase with the uptime of the cluster.
Name | Type | Description |
---|---|---|
iops_raw |
The number of I/O operations observed at the storage object. This should be used along with delta time to calculate the rate of I/O operations per unit of time. |
|
latency_raw |
The raw latency in microseconds observed at the storage object. This should be divided by the raw IOPS value to calculate the average latency per I/O operation. |
|
status |
string |
Any errors associated with the sample. For example, if the aggregation of data over multiple nodes fails then any of the partial errors might be returned, "ok" on success, or "error" on any internal uncategorized failure. Whenever a sample collection is missed but done at a later time, it is back filled to the previous 15 second timestamp and tagged with "backfilled_data". "Inconsistent_delta_time" is encountered when the time between two collections is not the same for all nodes. Therefore, the aggregated value might be over or under inflated. "Negative_delta" is returned when an expected monotonically increasing value has decreased in value. "Inconsistent_old_data" is returned when one or more nodes do not have the latest data. |
throughput_raw |
Throughput bytes observed at the storage object. This should be used along with delta time to calculate the rate of throughput bytes per unit of time. |
|
timestamp |
string |
The timestamp of the performance data. |
svm
SVM, applies only to SVM-scoped objects.
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
The name of the SVM. This field cannot be specified in a PATCH method. |
uuid |
string |
The unique identifier of the SVM. This field cannot be specified in a PATCH method. |
fc_interface
A Fibre Channel (FC) interface is the logical endpoint for FC network connections to an SVM. An FC interface provides FC access to storage within the interface SVM using either Fibre Channel Protocol or NVMe over Fibre Channel (NVMe/FC).
An FC interface is created on an FC port which is located on a cluster node. The FC port must be specified to identify the location of the interface for a POST or PATCH operation that relocates an interface. You can identify the port by supplying either the cluster node and port names or the port UUID.
Name | Type | Description |
---|---|---|
_links |
||
comment |
string |
A user configurable comment. Optional in POST; valid in PATCH. To clear a prior comment, set the property to an empty string in PATCH. |
data_protocol |
string |
The data protocol for which the FC interface is configured. Required in POST. |
enabled |
boolean |
The administrative state of the FC interface. The FC interface can be disabled to block all FC communication with the SVM through this interface. Optional in POST and PATCH; defaults to true (enabled) in POST. |
location |
The location of the FC interface is defined by the location of its port. An FC port is identified by its UUID, or a combination of its cluster node name and port name. Either the UUID or the cluster node name and port name are required for POST. To move an interface, supply either the port UUID or the cluster node name and port name in a PATCH.
|
|
metric |
Performance numbers, such as IOPS latency and throughput |
|
name |
string |
The name of the FC interface. Required in POST; optional in PATCH. |
port_address |
string |
The port address of the FC interface. Each FC port in an FC switched fabric has its own unique FC port address for routing purposes. The FC port address is assigned by a switch in the fabric when that port logs in to the fabric. This property refers to the address given by a switch to the FC interface when the SVM performs a port login (PLOGI). This is useful for obtaining statistics and diagnostic information from FC switches. This is a hexadecimal encoded numeric value. |
state |
string |
The current operational state of the FC interface. The state is set to down if the interface is not enabled. If the cluster node hosting the port is down or unavailable, no state value is returned. |
statistics |
These are raw performance numbers, such as IOPS latency and throughput. These numbers are aggregated across all nodes in the cluster and increase with the uptime of the cluster. |
|
svm |
SVM, applies only to SVM-scoped objects. |
|
uuid |
string |
The unique identifier of the FC interface. Required in the URL. |
wwnn |
string |
The world wide node name (WWNN) of the FC interface SVM. The WWNN is generated by ONTAP when Fibre Channel Protocol or the NVMe service is created for the FC interface SVM.
|
wwpn |
string |
The world wide port name (WWPN) of the FC interface. The WWPN is generated by ONTAP when the FC interface is created.
|
error_arguments
Name | Type | Description |
---|---|---|
code |
string |
Argument code |
message |
string |
Message argument |
returned_error
Name | Type | Description |
---|---|---|
arguments |
array[error_arguments] |
Message arguments |
code |
string |
Error code |
message |
string |
Error message |
target |
string |
The target parameter that caused the error. |