This may take a few minutes. Thanks for your patience.
Your file is ready
You can configure settings to monitor alerts on your NetApp HCI system.
NetApp HCI alert monitoring forwards NetApp HCI storage cluster system alerts to vCenter Server, enabling you to view all alerts for NetApp HCI from the vSphere Web Client interface.
Open the per-node management node UI (https://[IP address]:442).
Select the Alert Monitor tab.
Configure the alert monitoring options.
Alert monitoring options
options
Description
Run Alert Monitor Tests
Runs the monitor system tests to check for the following:
NetApp HCI and VMware vCenter connectivity
Pairing of NetApp HCI and VMware vCenter through datastore information supplied by the QoSSIOC service
Current NetApp HCI alarm and vCenter alarm lists
Collect Alerts
Enables or disables the forwarding of NetApp HCI storage alarms to vCenter. You can select the target storage cluster from the drop-down list. The default setting for this option is Enabled.
Collect Best Practice Alerts
Enables or disables the forwarding of NetApp HCI storage Best Practice alerts to vCenter. Best Practice alerts are faults that are triggered by a sub-optimal system configuration. The default setting for this option is Disabled. When disabled, NetApp HCI storage Best Practice alerts do not appear in vCenter.
Send Support Data To AIQ
Controls the flow of support and monitoring data from
VMware vCenter to NetApp SolidFire Active IQ.
Options are the following:
Enabled: All vCenter alarms, NetApp HCI storage alarms, and support data are sent to NetApp SolidFire Active IQ. This enables NetApp to proactively support and monitor the NetApp HCI installation, so that possible problems can be detected and resolved before affecting the system.
Disabled: No vCenter alarms, NetApp HCI storage alarms, or support data are sent to NetApp SolidFire Active IQ.
If you turned off the Send data to AIQ option using NetApp Deployment Engine, you need to enable telemetry again using the management node REST API to configure the service from this page.
Send Compute Node Data To AIQ
Controls the flow of support and monitoring data from the compute nodes to NetApp SolidFire Active IQ.
Options are the following:
Enabled: Support and monitoring data about the compute nodes is transmitted to NetApp SolidFire Active IQ to enable proactive support for the compute node hardware.
Disabled: Support and monitoring data about the compute nodes is not transmitted to NetApp SolidFire Active IQ.
If you turned off the Send data to AIQ option using NetApp Deployment Engine, you need to enable telemetry again using the management node REST API to configure the service from this page.