Validate firmware installation
After the execution of the playbook, log in to the cluster as the cluster administrator.
Validate disk firmware installation
-
Verify that the drive firmware is installed:
::*> storage disk show -fields firmware-revision,model disk firmware-revision model --------------- ----------------- ---------------- 1.11.0 NA01 X423_HCOBE900A10 1.11.1 NA01 X423_HCOBE900A10 1.11.2 NA01 X423_HCOBE900A10 1.11.3 NA01 X423_HCOBE900A10 1.11.4 NA01 X423_HCOBE900A10
For more information about the command, refer to storage disk show.
-
Verify that the new NVMe Flash Cache firmware is installed:
::*> system controller flash-cache show
For more information about the command, refer to system controller flash-cache show.
Validate shelf firmware installation
-
Verify that the new shelf firmware is updated:
::*> system node run -node * -command sysconfig -v
In the output, verify that each shelf's firmware is updated to the desired level. For example:
Shelf 1: IOM6 Firmware rev. IOM6 A: 0191 IOM3 B: 0191
For more information about the command, refer to system node run.
-
Verify that the new ACP firmware is updated:
::*> storage shelf acp module show -instance
For more information about the command, refer to storage shelf acp module show.
-
Verify that the desired ACP mode is configured:
::*> storage shelf acp show
For more information about the command, refer to storage shelf acp show.
-
Change the ACP mode (channel):
::*> storage shelf acp configure -channel [in-band | out-of-band]
For more information about the command, refer to storage shelf acp configure.
Validating SP/BMC Firmware installation
The Ansible Playbook for Service Processor/BMC firmware updates is enabled with an option to verify the installation of latest SP/BMC firmware on the controller. After the verification is complete (the updates could take a maximum time of two hours), the Ansible Playbook applies internal switch firmware updates by connecting to the SP/BMC console.
The failure and success information for SP/BMC firmware and the internal switch firmware installations will be notified at the end of Ansible Playbook execution. Follow the steps mentioned in the Ansible Playbook in case the SP/BMC firmware/internal switch firmware installation fails.