English

Validate firmware installation

Contributors netapp-manishc Download PDF of this page

After the execution of the playbook, log in to the cluster as the cluster administrator.

Validate disk firmware installation

Steps
  1. Verify that the drive firmware is installed:

    ::*> storage disk show -fields firmware-revision,model
    disk     firmware-revision model
    --------------- ----------------- ----------------
    1.11.0   NA01              X423_HCOBE900A10
    1.11.1   NA01              X423_HCOBE900A10
    1.11.2   NA01              X423_HCOBE900A10
    1.11.3   NA01              X423_HCOBE900A10
    1.11.4   NA01              X423_HCOBE900A10

    For more information about the command, refer to storage disk show.

  2. Verify that new NVMe Flash Cache firmware is installed:

    ::*> system controller flash-cache show

    For more information about the command, refer to system controller flash-cache show.

Validate shelf firmware installation

Steps
  1. Verify that the new shelf firmware is updated:

    ::*> system node run -node * -command sysconfig -v

    In the output, verify that each shelf’s firmware is updated to the desired level. For example:

    Shelf 1: IOM6 Firmware rev. IOM6 A: 0191 IOM3 B: 0191

    For more information about the command, refer to system node run.

  2. Verify that the new ACP firmware is updated:

    ::*> storage shelf acp module show -instance

    For more information about the command, refer to storage shelf acp module show.

  3. Verify that the desired ACP mode is configured:

    ::*> storage shelf acp show

    For more information about the command, refer to storage shelf acp show.

  4. Change the ACP mode (channel):

    ::*> storage shelf acp configure -channel [in-band | out-of-band]

    For more information about the command, refer to storage shelf acp configure.