Skip to main content
Amazon FSx for NetApp ONTAP

Replicate a storage VM to another FSx for ONTAP file system

Contributors netapp-rlithman

Replicating a storage VM to another FSx for ONTAP file system in BlueXP workload factory provides a protective layer of data access in case of data loss. This operation replicates all volumes in one storage VM to another FSx for ONTAP file system.

Before you begin

To replicate a storage VM to another FSx for ONTAP file system, you must associate a link. If you don't have an existing link, create a link. To associate a link in the file system, select Associate link under Account name. Once the link associates, return to this operation.

Steps
  1. Log in using one of the console experiences.

  2. In Storage, select Go to storage inventory.

  3. In the FSx for ONTAP tab, select the three-dot menu of the file system with the storage VM to replicate and then select Manage.

  4. From the file system overview, select the Storage VMs tab.

  5. From the Storage VMs tab, select the three-dot menu of the storage VM to replicate an SVM for.

  6. Select Replicate storage VM.

  7. On the Create replication page, under Replication target, provide the following:

    1. FSx for ONTAP file system: Select credentials, region, and FSx for ONTAP file system name for the target FSx for ONTAP file system.

    2. Storage VM name: Select the storage VM from the dropdown menu.

    3. Volume name: The target volume name is generated automatically with the following format {OriginalVolumeName}_copy.

    4. Tiering policy: Select the tiering policy for the data stored in the target volume.

      Auto is the default tiering policy when creating a volume using the workload factory FSx for ONTAP user interface. For more information about volume tiering policies, refer to Volume storage capacityin AWS FSx for NetApp ONTAP documentation.

    5. Max transfer rate: Select Limited and enter the max transfer limit in MB/s. Alternatively, select Unlimited.

      Without a limit, network and application performance may decline. Alternatively, we recommend an unlimited transfer rate for FSx for ONTAP file systems for critical workloads, for example, those that are used primarily for disaster recovery.

  8. Under Replication settings, provide the following:

    1. Replication interval: Select the frequency that snapshots are transferred from the source volume to the target volume.

    2. Long-term retention: Optionally, enable snapshots for long-term retention.

      If you enable long-term retention, then select an existing policy or create a new policy to define the snapshots to replicate and the number to retain.

      1. For Choose an existing policy, select an existing policy from the dropdown menu.

      2. For Create a new policy, provide the following:

        1. Policy name: Enter a policy name.

        2. Snapshot policies: In the table, select the snapshot policy frequency and the number of copies to retain. You can select more than one snapshot policy.

  9. Select Create.

Result

All volumes within the storage VM are replicated to the target file system.