When storage errors show flags an error condition, you need to determine why the error occurred and how to fix it.

The following table lists the back-end configuration errors detected by storage errors show and refers you to detailed information about the causes of each error and its resolution.

storage errors show message For more information about this message see…​

NAME (Serial #): All paths to this array LUN are connected to the same fault domain. This is a single point of failure`.

NAME (Serial #), port WWPN1: LUN 1 occurs more than once. LUNs cannot be reused on the same array target port.

NAME (Serial #): This array LUN is an access control LUN. It is not supported and should be masked off or disabled`.

NAME (Serial #) This array LUN is configured with conflicting failover modes. Each path to this LUN must use the same mode.

NAME (Serial #): This Array LUN is only available on one path. Proper configuration requires two paths.

NAME (Serial #): This array LUN is too large and is not usable. The maximum array LUN size supported is xTB.

NAME (Serial #): This array LUN is too small and is not usable. The minimum array LUN size supported is 1GB.

NAME (Serial #): This Array LUN is using multiple LUN IDs. Only one LUN ID per serial number is supported.

Volume Set Addressing is inconsistent

NAME (Serial #): This array LUN is marked foreign and has a reservation.