Skip to main content
StorageGRID Appliances

Relocate SG110 and SG1100 in cabinet or rack

Contributors netapp-perveilerk

Remove the SG110 or SG1100 from a cabinet or rack to access the top cover or to move the appliance to a different location, then reinstall the appliance into a cabinet or rack when hardware maintenance is complete.

Remove SG110 or SG1100 from cabinet or rack

Before you begin
Steps
  1. Label and then disconnect the appliance power cables.

  2. Wrap the strap end of the ESD wristband around your wrist, and secure the clip end to a metal ground to prevent static discharge.

  3. Label and then disconnect the appliance data cables and any SFP+ or SFP28 transceivers.

    Important To prevent degraded performance, don't twist, fold, pinch, or step on the cables.
  4. Loosen the two captive screws on the appliance front panel.

    SG110 or SG1100 rack retaining screws
  5. Slide the SG110 or SG1100 forward out of the rack until the mounting rails are fully extended and you hear the latches on both sides click.

    The appliance top cover is accessible.

  6. Optional: If you are fully removing the appliance from the cabinet or rack, follow the instructions for the rail kit to remove the appliance from the rails.

After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return & Replacements page for further information.

Reinstall SG110 or SG1100 into cabinet or rack

Before you begin

You have reinstalled the appliance cover.

Steps
  1. Press the blue rail releases both rack rails at the same time and slide the SG110 or SG1100 into the rack until it is fully seated.

    When you can't move the controller any further, pull the blue latches on both sides of the chassis to slide the controller all the way in.

    SG110 or SG1100 sliding on rails
    Note Don't attach the front bezel until after you power on the controller.
  2. Tighten the captive screws on the controller front panel to secure the controller in the rack.

    SG110 or SG1100 rack retaining screws
  3. Wrap the strap end of the ESD wristband around your wrist, and secure the clip end to a metal ground to prevent static discharge.

  4. Reconnect the controller data cables and any SFP+ or SFP28 transceivers.

    Important To prevent degraded performance, don't twist, fold, pinch, or step on the cables.
  5. Reconnect the controller power cables.

After you finish

Restart the appliance.