Power down host
Before you power down a host, you must stop services on all grid nodes on that host.
-
Log in to the grid node:
-
Enter the following command:
ssh admin@grid_node_IP
-
Enter the password listed in the
Passwords.txt
file. -
Enter the following command to switch to root:
su -
-
Enter the password listed in the
Passwords.txt
file.
When you are logged in as root, the prompt changes from
$
to#
. -
-
Stop all services running on the node:
service servermanager stop
Services can take up to 15 minutes to shut down, and you might want to log in to the system remotely to monitor the shutdown process.
-
Repeat steps 1 and 2 for each node on the host.
-
If you have a Linux host:
-
Log in to the host operating system.
-
Stop the node:
storagegrid node stop
-
Shut down the host operating system.
-
-
If the node is running on a VMware virtual machine or it is an appliance node, issue the shutdown command:
shutdown -h now
Perform this step regardless of the outcome of the
service servermanager stop
command.After you issue the shutdown -h now
command on an appliance node, you must power cycle the appliance to restart the node.For the appliance, this command shuts down the controller, but the appliance is still powered on. You must complete the next step.
-
If you are powering down an appliance node, follow the steps for your appliance.
SG6160-
Turn off the power to the SG6100-CN storage controller.
-
Wait for the blue power LED on the SG6100-CN storage controller to turn off.
SGF6112-
Turn off the power to the appliance.
-
Wait for the blue power LED to turn off.
SG6000-
Wait for the green Cache Active LED on the back of the storage controllers to turn off.
This LED is on when cached data needs to be written to the drives. You must wait for this LED to turn off before you turn off power.
-
Turn off the power to the appliance, and wait for the blue power LED to turn off.
SG5800-
Wait for the green Cache Active LED on the back of the storage controller to turn off.
This LED is on when cached data needs to be written to the drives. You must wait for this LED to turn off before you turn off power.
-
From the home page of SANtricity System Manager, select View Operations in Progress.
-
Confirm that all operations have completed before continuing with the next step.
-
Turn off both power switches on the controller shelf, and wait for all LEDs on the controller shelf to turn off.
SG5700-
Wait for the green Cache Active LED on the back of the storage controller to turn off.
This LED is on when cached data needs to be written to the drives. You must wait for this LED to turn off before you turn off power.
-
Turn off the power to the appliance, and wait for all LED and seven-segment display activity to stop.
SG110 or SG1100-
Turn off the power to the appliance.
-
Wait for the blue power LED to turn off.
SG100 or SG1000-
Turn off the power to the appliance.
-
Wait for the blue power LED to turn off.
-
-
Log out of the command shell:
exit