Prepare for installation
You must prepare your site to meet the specifications for your E4000 series storage system.
-
Create an account and register your hardware at NetApp Support.
-
Ensure the following items are in the box you received:
E4012- Shelf with drives installed (bezel packaged separately)
-
- Rack-mount hardware
-
- Ethernet cables for management connection (if ordered)
-
- I/O cables for cabling data hosts
-
- Power cables
-
- SAS cables
-
E4060- Shelf, bezel, and rackmount hardware
-
- Four shelf handles x4
-
- Ethernet cables for management connection (if ordered)
-
- I/O cables for cabling data hosts
-
- Power cables
-
- SAS cables
-
-
Obtain the additional items needed for installation:
-
A philips #2 screwdriver
-
A flashlight
-
An ESD strap
-
A cabinet or rack fits shelves of the following sizes:
E4012Depth: 21.1. in (53.59 cm)
Width: 17.64 in (44.8)
Height: 3.4 in (8.64 cm)
Max Weight: 65.25 lb (29.6 kg)
E4060Depth: 36.3 in (92.2 cm)
Width: 17.64 in (44.8 cm)
Height: 7.0 in (17.78 cm)
Max Weight: 253.33 lb (114.91 kg)
-
A location providing the correct voltage of AC power:
-
E4012: 120 to 240-volt AC
-
E4060: 240-volt AC
-
-
A supported browser for the management software:
-
Google Chrome (version 89 and later)
-
Microsoft Edge (version 90 and later)
-
Mozilla Firefox (version 80 and later)
-
Safari (version 14 and later)
-
-