Skip to main content
E-Series Systems

Complete storage system setup and configuration

Contributors netapp-driley NetAppZacharyWambold netapp-jsnyder

Learn how to connect the controller cables to your network, and then complete the setup and configuration.

Step 1: Cable the data hosts

Cable the storage system according to your network topology.

Option 1: Direct-attach topology

The following example shows cabling to the data hosts using a direct-attach topology.

Table 1. Example A: Direct-attach topology

Direct-attach topology cabling

  1. Connect each host adapter directly to the host ports on the controllers.

Option 2: Fabric topology

The following example shows cabling to the data hosts using a fabric topology.

Table 2. Example B: Fabric topology

Fabric topology cabling

  1. Connect each host adapter directly to the switch.

  2. Connect each switch directly to the host ports on the controllers.

Step 2: Connect and configure the management connection

You can configure the controller management ports using a DHCP server or a static IP address.

Option 1: DHCP server

Learn how to configure the management ports with a DHCP server.

Before you begin
  • Configure your DHCP server to associate an IP address, subnet mask, and gateway address as a permanent lease for each controller.

  • Obtain the assigned IP addresses you will use to connect to the storage system from your network administrator.

Steps
  1. Connect an Ethernet cable to each controller's management port, and connect the other end to your network.

    RJ-45 cables

    RJ-45 Ethernet cables (if ordered)

    The following figure shows an example of the controller's management port location (EF600 shown):

    EF600 management ports

  2. Open a browser and connect to the storage system using one of the controller IP addresses provided to you by your network administrator.

Option 2: Static IP address

Learn how to configure the management ports manually by entering the IP address and the subnet mask.

Before you begin
  • Obtain the controllers' IP address, subnet mask, gateway address, and DNS and NTP server information from your network administrator.

  • Make sure that the laptop you are using is not receiving network configuration from a DHCP server.

Steps
  1. Using an Ethernet cable, connect controller A's management port to the Ethernet port on a laptop.

    Note Controller A is the upper controller canister, and controller B is the lower controller canister.

    RJ-45 cables"

    RJ-45 Ethernet cables (if ordered)

    The following figure shows an example of the controller's management port location (EF600 shown):

    EF600 management ports

  2. Open a browser and use the default IP address (169.254.128.101) to establish a connection to the controller. The controller sends back a self-signed certificate. The browser informs you that the connection is not secure.

    Note For platforms running SANtricity 11.60 and greater, the default subnet mask is 255.255.0.0.
  3. Follow the browser's instructions to proceed and launch SANtricity System Manager.

    Note If you are unable to establish a connection, verify that you are not receiving network configuration from a DHCP server.
  4. Set the storage system's password to login.

  5. Use the network settings provided by your network administrator in the Configure Network Settings wizard to configure controller A's network settings, and then select Finish.

    Note Because you reset the IP address, System Manager loses connection to the controller.
  6. Disconnect your laptop from the storage system, and connect the management port on controller A to your network.

  7. Open a browser on a computer connected to your network, and enter controller A's newly configured IP address.

    Note If you lose the connection to controller A, you can connect an ethernet cable to controller B to reestablish connection to controller A through controller B (169.254.128.102).
  8. Log in using the password you set previously.

    The Configure Network Settings wizard will appear.

  9. Use the network settings provided by your network administrator in the Configure Network Settings wizard to configure controller B's network settings, and then select Finish.

  10. Connect controller B to your network.

  11. Validate controller B's network settings by entering controller B's configured IP address in a browser.

    Note If you lose the connection to controller B, you can use your previously validated connection to controller A to reestablish connection to controller B through controller A.

Step 3: Configure storage system

After you have installed the EF300 or EF600 hardware, use the SANtricity software to configure and manage your storage system.

Before You Begin
  • Configure your management ports.

  • Verify and record your password and IP addresses.

Steps
  1. Connect your controller to a web browser.

  2. Use SANtricity System Manager to manage your EF300 or EF600 series storage system. Refer to the online help included with System Manager.

    Access System Manager to configure your management ports

    For accessing System Manager, use the same IP addresses that you used to configure your management ports.

If you are cabling your EF300 for SAS expansion, see Maintaining EF600 Hardware for SAS expansion card installation and the Cabling E-Series hardware for SAS expansion cabling.