Skip to main content

Move non-root aggregates and NAS data LIFs owned by node2 from node3 to node4

Contributors netapp-pcarriga netapp-aoife

After you verify the node4 installation and before you relocate aggregates from node3 to node4, you must move the NAS data LIFs belonging to node2 that are currently on node3 from node3 to node4. You also need to verify the SAN LIFs exist on node4.

About this task

Remote LIFs handle traffic to SAN LUNs during the upgrade procedure. Moving SAN LIFs is not necessary for cluster or service health during the upgrade. SAN LIFs are not moved unless they need to be mapped to new ports. You will verify that the LIFs are healthy and located on appropriate ports after you bring node4 online.

Steps
  1. Resume the relocation operation:

    system controller replace resume

    The system performs the following tasks:

    • Cluster quorum check

    • System ID check

    • Image version check

    • Target platform check

    • Network reachability check

    The operation pauses at this stage in the network reachability check.

  2. Manually verify that the network and all VLANs, interface groups, and broadcast domains have been configured correctly.

  3. Resume the relocation operation:

    system controller replace resume

    To complete the "Network Reachability" phase, ONTAP network configuration must be manually adjusted to match the new physical network configuration of the hardware. This includes assigning network ports to the correct broadcast domains,creating any required ifgrps and VLANs, and modifying the home-port parameter of network interfaces to the appropriate ports.Refer to the "Using aggregate relocation to upgrade controller hardware on a pair of nodes running ONTAP 9.x" documentation, Stages 3 and 5. Have all of these steps been manually completed? [y/n]
  4. Enter y to continue.

  5. The system performs the following checks:

    • Cluster health check

    • Cluster LIF status check

    After performing these checks, the system relocates the non-root aggregates and NAS data LIFs owned by node2 to the new controller, node4.
    The system pauses once the resource relocation is complete.

  6. Check the status of the aggregate relocation and NAS data LIF move operations:

    system controller replace show-details

  7. Manually verify that the non-root aggregates and NAS data LIFs have been successfully relocated to node4.

    If any aggregates fail to relocate or are vetoed, you must take manually relocate the aggregates, or override either the vetoes or destination checks, if necessary. See the section Relocate failed or vetoed aggregates for more information.

  8. Confirm that the SAN LIFs are on the correct ports on node4 by completing the following substeps:

    1. Enter the following command and examine its output:

      network interface show -data-protocol iscsi|fcp -home-node node4

      The system returns output similar to the following example:

      cluster::> net int show -data-protocol iscsi|fcp -home-node node3
              Logical    Status     Network           Current Current Is
      Vserver Interface  Admin/Oper Address/Mask      Node    Port    Home
      ------- ---------- ---------- ----------------- ------- ------- ---
      vs0
              a0a        up/down    10.63.0.53/24     node3   a0a     true
              data1      up/up      10.63.0.50/18     node3   e0c     true
              rads1      up/up      10.63.0.51/18     node3   e1a     true
              rads2      up/down    10.63.0.52/24     node3   e1b     true
      vs1
              lif1       up/up      172.17.176.120/24 node3   e0c     true
              lif2       up/up      172.17.176.121/24 node3   e1a     true
    2. If node4 has any SAN LIFs or groups of SAN LIFs that are on a port that did not exist on node2 or that need to be mapped to a different port, move them to an appropriate port on node4 by completing the following substeps:

      1. Set the LIF status to down by entering the following command:

        network interface modify -vserver vserver_name -lif lif_name -status-admin down

      2. Remove the LIF from the port set:

        portset remove -vserver vserver_name -portset portset_name -port-name port_name

      3. Enter one of the following commands:

        • Move a single LIF by entering the following command:

          network interface modify -vserver vserver_name -lif lif_name -home-port new_home_port

        • Move all the LIFs on a single nonexistent or incorrect port to a new port by entering the following command:

          network interface modify {-home-port port_on_node1 -home-node node1 -role data} -home-port new_home_port_on_node3

        • Add the LIFs back to the port set:

          portset add -vserver vserver_name -portset portset_name -port-name port_name

          Note You must confirm that you move SAN LIFs to a port that has the same link speed as the original port.
    3. Modify the status of all LIFs to up so the LIFs can accept and send traffic on the node by entering the following command:

      network interface modify -home-port port_name -home-node node4 -lif data -statusadmin up

    4. Enter the following command and examine its output to verify that LIFs have been moved to the correct ports and that the LIFs have the status of up by entering the following command on either node and examining the output:

      network interface show -home-node <node4> -role data

    5. If any LIFs are down, set the administrative status of the LIFs to up by entering the following command, once for each LIF:

      network interface modify -vserver vserver_name -lif lif_name -status-admin up

  9. Resume the operation to prompt the system to perform the required post-checks:

    system controller replace resume

    The system performs the following post-checks:

    • Cluster quorum check

    • Cluster health check

    • Aggregates reconstruction check

    • Aggregate status check

    • Disk status check

    • Cluster LIF status check